34
The above table suggests that carrier frequency shall influence electromagnetic noise. the drive’s heat dissipation
as well as interference to the environment of motor; thus, decreasing the carrier frequency shall help the motor
drive to decrease temperature rise if ambient noise exceeds noise of the motor; in case of high load wave
frequency, although operation noise shall be eliminated to a large degree, attention shall be paid to the
interference and protection of the machine.
Note:7.5 kW and above, if the carrier frequency is higher than 8 kHz, it can allow max. current output will be
slightly reduced, at the same time, if the carrier frequency is higher , then inverter and motor heating will be higher,
in the case of noise does not affect ,the carrier shall be reduced.
2 External Terminal Parameters
02-00
2 wire style/3 wire operation control
Factory setting
0
Setting range
0:Forward run/stop, Reverse run/stop
1:Run/stop, Reverse run/forward run
2:Three line operation control
This parameter sets the external control operation configuration of AC moter drive, there are three different
control modes:
02-00
External terminal control circuit
0
2 wire
FWD /Stop
REV/ Stop
DCM
REV "Open"
:
Stop; "Close"
:
REV
RUN/STOP
REV/FWD
FWD "Open"
:
Stop; "Close"
:
FWD
1
2 wire
FWD / Stop
REV /Fwd
DCM
REV "Open"
:
FWD; "Close"
:
REV
RUN/STOP
REV/FWD
FWD "Open"
:
Stop; "Close"
:
Run
2
3 wire style
DCM
STOP
RUN
REV/FWD
FWD "Close"
:
Run
EF
"Open"
:
Stop
REV
"Open"
:
FWD; "Close"
:
REV
02-01
Multi-functional input option 1
Factory setting
3
02-02
Multi-functional input option 2
1
02-03
Multi-functional input option 3
2
Setting
range
0:Multi-step speed command 1
1:Multi-step speed command 2
2:Multi-step speed command 3