43
05-08
Jog running frequency setting
Factory setting
7.00
Setting range 0.10
~
600.00Hz
When the AC motor drive receives the Jogging command , this parameter is set output Jogging frequency value
of the AC motor drive.
05-09
Jog acceleration/deceleration time setting
Factory setting
3.00
Setting range 0.10
~
400.00S
This parameter determines this time(Jogging acceleration/deceleration time) required for the AC Drive to ramp
from 0 Hz to the max. output frequency (01-02) and this time(Jogging acceleration/deceleration time) required to
ramp from the max. output frequency(01-02) to 0 Hz.
05-10
Setting of S curve acceleration/deceleration time(reserved)
Factory setting
0
Setting range
0
~
100