30
SATEL
ACCO
Clock correction
The function enables the clock settings to be adjusted once every 24 hours (at midnight) by
a defined time, if the module clock is inadequate. The correction time is programmed in
seconds. The maximum correction can be ±15 seconds per 24 hours.
Summer time (DST)
The module can automatically adjust the clock settings due to the change from standard time
to summer time (DST) and vice versa. The following correction schemes can be selected:
−
no correction
−
correction according to the European Union rules
−
correction by 1 hour according to dates
−
correction by 2 hours according to dates
Summer time begins
The function is available, if the module clock settings are to be corrected by 1 or 2 hours
according to dates. It enables entering the date (day, month) when the module clock is
changed to summer time (shifted forward).
Summer time ends
The function is available, if the module clock settings are to be corrected by 1 or 2 hours
according to dates. It enables entering the date (day, month) when the module clock is
changed to standard time (shifted back).
5.4 Functions and options related to the door
Relay off when door open
If this option is enabled, the relay controlling the door activation device will be switched off as
soon as the door is opened.
Relay off when door closed
If this option is enabled, the relay controlling the door activation device will be switched off as
soon as the open door is closed.
Notes:
•
If none of the options determining the moment of switching the relay off is enabled, the
relay will only be switched off after expiry of the A
CCESS TIME
.
•
In the following cases the relay will be switched off after expiry of the A
CCESS TIME
, despite
enabling one of the options which determine the moment of switching the relay off:
–
none of the inputs informs about the door status (the door status monitoring sensor has
not been installed),
–
the D
ISABLE DOOR STATUS CONTROL
option has been enabled,
–
the user has got access, but has not opened the door.
Disable door status control
Enabling this option is recommended if no information on the door status can reach the
module (the status sensor has got damaged or, for some reason, has not been connected).
This will prevent generating wrong events. When the option is enabled, unlocking the door is
recognized as equivalent to opening the door. This means that unlocking the door from the
terminal A side will generate the event informing about entry without door status control, and
from the terminal B side – about exit without door status control. Some events are not
generated (e.g. events informing about forced opening of the door, long open door, etc.).