ACCO
SATEL
15
1
2
3
4
5
Fig. 11. An example of access control installation.
Explanations for Fig. 11:
1 –
door controller module
.
2 –
controlled door activator
(electromagnetic lock controlled from the module relay
output).
3 –
controlled door sensor
(magnetic detector connected to the module input
programmed as D
OOR STATUS CONTROL
).
4 –
exit
terminal
(proximity card reader connected as reader B).
5 –
entry terminal
(proximity card reader connected as reader A).
3.1 Connecting the ACCO-KLCDR-BG / ACCO-KLCDR-BW keypad
The LCD keypad can be connected to the module by means of the terminals on electronics
board or the RJ socket. Use four-core cable for making the connection. The distance
between the keypad and the module can be up to 300m.
The module supports keypads with addresses 0 and 1. The keypad with address 0 will
serve as terminal A (entry terminal). The keypad with address 1 will serve as terminal B