Two-way wireless system ABAX
ACU-100
22
1st digit
2nd digit
3rd digit
digit signaling
duration digit acoustic signaling
digit
optical signaling
1 1
minute 0
none
0 disabled
2
3 minutes
1
sound type 1
1
enabled
3
6 minutes
2
sound type 2
-
-
4
9 minutes
3
sound type 3
-
-
Table 8.
A command to trigger the signaling is only send to the siren during the response time.
Hence the cutoff time of the control panel outputs which control the ASP-205 wireless indoor
siren must be longer than the response time. It is recommended that this time correspond to
the signaling duration, as programmed in the siren.
Violation of the siren tamper contact will generate tamper alarm, which will last 3 minutes
(sound type 1 and optical signaling). For 40 seconds after power-up and during the T
EST
MODE
, and in case of the controller operation with the INTEGRA control panel - also during
the service mode, the tamper alarm signaling is blocked. This is indicated by blinking LEDs of
the siren.
When the ACU-100 controller operates together with the INTGERA control panel, the siren
takes up 2 zones and 2 outputs in the alarm system. The outputs which are to trigger
signaling must be suitably programmed. Information on the siren battery status is supplied to
both zones.
If the ACU-100 controller operates together with the CA-64 control panel, the siren takes up
two zones in the alarm system and information on the siren battery status is supplied to both
of them. In order to activate the signaling, indicate the control inputs for each position taken
up by the siren and then connect these inputs to suitably programmed outputs of the control
panel.
If the ACU-100 controller works together with another control panel, the number of zones that
will be occupied in the system by the siren will depend on the system installer. He can assign
both positions taken up by the siren to one controller output, and so just one zone will be
taken up in the alarm system. Information on the siren battery status will be send to this zone.
Similarly as with the CA-64 control panel, to trigger signaling you must indicate control inputs
for both positions occupied by the siren, and then connect these inputs to the suitably
programmed outputs of the control panel.
4.10 ASW-100
230V
AC
WIRELESS CONTROLLERS IN
ABAX
SYSTEM
Before plugging the ASW-100 wireless controller into the 230V socket, familiarize
yourself thoroughly with the electrical system in the premises. The phase conductor in
the socket into which the controller is to be plugged should be on the left-hand side,
and the neutral conductor - on the right-hand side.
To install the ASW-100 E or ASW-100 F controller in the ABAX system, proceed as follows:
1. Add the ASW-100 controller to the wireless system (refer: A
DDING NEW WIRELESS DEVICES
).
2. Plug the ASW-100 controller into the selected 230V socket.
3. Check the level of signal received by the ASW-100 controller from the ACU-100
controller. If necessary, select another socket and re-check the signal level.
4. Having obtained the optimum signal level, configure the ASW-100 controller as required.
The 230V AC wireless controller takes up 1 position on the list of wireless devices supported
by the ACU-100 controller.