ACU-100 SATEL
23
The ASW-100 E and ASW-100 F controllers can work in three modes (given in square
brackets is mode description in the LCD keypad of INTEGRA system):
−
mode 0 [button: inactive] – the electric circuit is only remotely controlled;
−
mode 1 [button: interim control] – the electric circuit can be controlled remotely or
manually;
−
mode 2 [button: combined control] – the electric circuit can be controlled remotely or
manually, but remote control can be manually overridden.
The operating mode in the LCD keypad is programmed by means of the C
ONFIGURATION
function. The
S
and
T
keys are used for selection of the mode. In the D
LOAD
10 and D
LOAD
X
programs, click on the field corresponding to the ASW-100 controller operating mode in the
„Configuration” column and then enter 0 for mode 0, 1 for mode 1 or 2 for mode 2. The new
settings are sent to the controller during the response time (see: R
ESPONSE PERIOD
).
The commands to close / open the 230V electric circuit are received by the ASW-100
controller from the ACU-100 controller in real time. If the ACU-100 controller operates in
configuration of expander of wireless devices for the INTEGRA control panels, the 230V
electric circuit status will change upon activation of the control panel output to which the
ASW-100 controller is assigned. The control panel output shall be configured to suit the
needs. If the ACU-100 controller is otherwise configured, the 230V electric circuit status will
change upon activation of the control input selected for the ASW-100 controller. A suitably
programmed output of the control panel should be connected to the control input of the
ACU-100 controller.
Depending on the operating mode, the ASW-100 controller will send to the ACU-100
controller information on the status of the ASW-100 controller button (mode 0) or on the
electric circuit status (mode 1 and mode 2). Information on the button status is sent in real
time. Information on the electric circuit status is sent during response time (see: R
ESPONSE
PERIOD
). If the ACU-100 controller is working together with the INTEGRA or CA-64 control
panel, pressing the button / closing the electric circuit will activate the alarm system zone to
which the ASW-100 controller is assigned. In other configurations, pressing the button /
closing the electric circuit will activate the ACU-100 controller output to which the ASW-100
controller is assigned. This output is to be connected to the control panel zone. The control
panel zone to which information on the status of button / 230V electric circuit is supplied,
should be suitably programmed.
When configuring the ASW-100 E or ASW-100 F controller, carefully select the F
ILTER
value,
i.e. the number of response periods with no response, after which loss of communication with
the ASW-100 controller will be reported. The 230V sockets are installed at low position,
hence the ASW-100 controllers mounted in them are exposed to the risk of being covered by
personnel moving around the premises.
4.11 R
ADIO SIGNAL LEVEL TESTER IN
ABAX
SYSTEM
The ARF-100 tester takes up one position on the list of devices supported by the ACU-100
controller. The tester enables checking the level of radio signal received either by the
controller from the tester, or by the tester from the controller. The signal level is displayed on
the tester LEDs, when the ACU-100 controller is running in the test mode.
Note:
Each tester has the serial number 0000500.
In order to check the radio signal level and find the optimum installation position for the
wireless device by means of the tester, do the following:
1. Install battery in the tester.
2. Add the tester to the wireless system (see: A
DDING NEW WIRELESS DEVICES
). If the
ACU-100 controller is configured for the expander operation with the CA-64 or INTEGRA