ACU-100 SATEL
41
•
D
LOAD
10
identifier: 0000000000000000;
•
response period: 24s;
•
problem signaling: LED indicator;
•
no registered wireless devices.
The default (factory) settings can be restored by means of the
S
ET DEFAULT
function
in the
keypad connected to the controller, or by way of
hardware restart
. In order to restore the
defaults by means of the hardware restart, follow the instructions below:
1. Disconnect the controller power supply.
2. Disconnect the cables connected to the controller communication bus.
3. Short the CLK and DAT terminals.
4. Reconnect the power supply. A short while after power-up, the operating mode LED
indicator will light in red. When default settings are restored, the LED color will change to
green.
5. Open the CLK and DAT terminals.
6. Disconnect the controller power supply.
7. Reconnect the cables to the controller communication bus.
8. Reconnect the controller power supply.
8. T
ECHNICAL DATA
Operating frequency band .....................................................................868.0MHz ÷ 868.6MHz
Number of supported wireless devices .................................................................................. 48
Range ...............................................................................................up to 150m (in open area)
Supply voltage, rated .......................................................................................... 12V DC ±15%
Current consumption, average............................ 60mA ÷ 120mA (depending on configuration)
Outputs current-carrying capacity .....................................................................................50mA
Working temperature range ......................................................................................... 0 ÷ 55°C
Housing dimensions, OPU-1 A .........................................................................126x158x32mm