control panels, it is recommended that the ARF-100 tester be added as the last wireless
device (after the other devices to be installed in the ABAX system). This will prevent
creating an unnecessary gap due to unused zone after the tester is removed from the
system.
3. Using the
designated button, select the power supply mode for the wireless device
which is to be installed and simulated by the tester.
4. Start the test mode in the controller. During response time, the level of radio signal
received by the tester from the controller will be displayed on the LED indicator. Press the
designated button to see the level of signal received by controller from the tester. The
signal level is always refreshed during the response time (which is signaled by 1 short
beep). If a higher update frequency is required, activate the dense polling mode by means
of the
button. The signal level displayed on the LEDs will be refreshed every 2
seconds. Information update will be signaled by 2 short beeps.
5. Find the optimum location to install the new wireless device.
6. Having completed the test, switch off the tester and remove it from the ABAX wireless
system.
Note:
If not used, the tester will switch off automatically after 10 minutes.
5. I
NTERACTION WITH ALARM CONTROL PANELS
The ACU-100 controller can work in several configurations:
- as expander of wireless devices for INTEGRA series control panels;
- as expander of addressable zones for CA-64 control panel;
- as expander of zones for CA-10 control panel;
- as wireless device module interfacing with any alarm control panel.
5.1 E
XPANDER OF WIRELESS DEVICES FOR
INTEGRA
SERIES CONTROL PANELS
Set the suitable operating mode and address of the controller on DIP-switches.
Fig. 7. Example of setting the DIP-switches.
Communication with the control panel is only effected by means of the communication bus.
This way is used for transmission of information on violations of detectors, tampers and
troubles of wireless devices, as well as for control of operation of wireless devices. Table 9
shows how the terminals of the controller communication bus should be connected to the
communication bus terminals of the INTEGRA alarm control panels.
operating mode:
INTEGRA control panel
address:
4