ACU-100 SATEL
19
6. Enter the test mode and set the required detector range. If necessary, modify the position
of electronics board (pyroelement) in the housing, or the position of installed detector.
Sensitivity of the APD-100 detectors is set by using the C
ONFIGURATION
functions. In the LCD
keypad, the sensitivity level can be changed by means of the arrow keys. In the D
LOAD
10
and D
LAOD
X programs, click the box corresponding to the detector whose sensitivity is to be
changed in the "Configuration" column, and then enter from the keypad a number from the 1
to 3 range as per Table 6.
Number
Detector sensitivity
1 low
2 medium
3 high
Table 6.
4.8.2 Installation of AMD-100, AMD-101 detectors
In order to install the AMD-100 or AMD-101 magnetic detector in the system you should:
1. Install battery in the detector.
2. Add the detector to the system (see: A
DDING NEW WIRELESS DEVICES
).
3. Select the location where you want the detector installed, and mount it temporarily in
position.
4. Check the level of signal received by the controller from the detector, and change the
detector installation place, if necessary.
5. Having reached the optimal signal level, install the detector permanently.
6. Enter the test mode and check the detector for proper functioning.
The AMD-101 wireless magnetic detector with an extra independent input occupies 2
positions on the list of devices supported by the controller (i.e. reed switch and the extra
input, to which an outdoor detector of NC type can be connected). This means that these
detectors will use 2 zones in the security system (unless the status of both detectors is
transmitted to the control panel by means of one controller output).
4.9 W
IRELESS SIGNALING DEVICES IN
ABAX
SYSTEM
The wireless sirens sent information on tampers and (storage) battery / power supply status
to the ACU-100 controller. The information on tampers is sent immediately, while all the other
information - at the response time (see: R
ESPONSE PERIOD
).
Note:
Tamper alarm signaling is blocked after starting the service mode in the event of
operation with the INTEGRA series control panels, or the T
EST MODE
in any other
configuration, and also for 40 seconds after connecting power supply to the siren.
4.9.1 Installation of ASP-105 sirens
To install the ASP-105 outdoor siren in the system, follow the procedure below:
1. Connect accumulator battery to the siren.
2. Add the siren to the system (see: A
DDING NEW WIRELESS DEVICES
).
3. Select the location where you want the siren to be installed, and mount it temporarily in
position.
4. Check the level of signal received by the controller from the siren, and, if necessary,
change the siren installation place.
5. Install the siren permanently and connect 12V DC external power supply to it.
6. Configure the siren as required.