SWITCH 1
39
40
Usa
ge of e
ach
featur
e
Usage of e
ach
fea
tur
e
●It activates the alarm at the time set at the beginning of
running and uses it as the guideline for the goal time.
1) Select [TIMER] with the multi-selector and determine with the
Enter operation.
2) Setting the
T
ype [TYPE]
Operate the Select button and select [INT] with [TYPE].
3) Setting Interval (INTER
VAL)
Set the Interval Timer with [INTER
V
AL].
4) Starting Interval Timer
As a default, the timer switch is set to SW1.
When holing SW1, the timer will be in the standby mode and
measuring will start when you press SW1 again or operate the
trigger.
5) Every time you operate SW1, the Interval Timer will be reset.
6) Completing measuring
By holding SW1, measuring will be completed.
*When turning the power switch off while the timer is activated,
the timer will be reset.
*When the timer is set to SW1/SW2, the timer will be in the standby
mode by holding the switch even on a screen other than the
setting screen.
● It can be a guideline for calculating running time of an electric
RC car and the fuel cost of an engine RC car.
● You can set for per second up to 99 : 59.
● When the timer switches to the Up Timer after the Down Timer
ends, you can check the lap time after the end.
1) Select [TIMER] with the multi-selector and determine with the
Enter operation.
2) Setting the
T
ype [TYPE]
Operate the Select button and select [DOWN] with [TYPE].
* Set the Down Timer with [GOA
L
-TIME] of SETUP.
3) Starting Down Timer
As a default, the timer switch is set to SW1.
When holing SW1, the timer will be in the standby mode and
measuring will start when you press SW1 again or operate the
throttle trigger.
4) Every time you operate SW1, the Down Timer will be reset.
5) Completing measuring
By holding SW1, measuring will be completed.
*When turning the power switch off while the timer is activated, the timer will be reset.
*When the timer is set to SW1, the timer will be in the standby mode by holding the switch
even on a screen other than the setting screen.
ENTER
BACK
TIMER
DOWN TIMER
LOG DATA
TIMER
ENTER
BACK
TELEMETRY
TELEMETRY
●A menu for setting
T
elemetry-related LOG D
AT
A, TELEMETRY SE
T
TING, GRAPH SE
T
TNG and TELEMETRY SWITCH.
●
T
o use the
T
elemetry feature, you can make it compatible by using a compatible receiver or sensors,
SUPER VORTEX series or S
V
-PLUS series.
●With
T
elemetr
y
, you can check the data of 2 temperature systems, battery voltage and number of
rotations with the transmitter.
・
LOG D
ATA
:
Menu for controlling log data that is being recorded
・
TELEMETRY SE
T
TING
:
V
arious settings of
T
elemetry features
・
GRAPH SE
T
TING
:
Setting for graph display
・
TELEMETRY SWITC
H
:
V
arious settings of the switch to activate
based on the
T
elemetry data.
●A feature to control the log data for creating a graph, saving onto an Micro SD card and deleting log
data by reading the recorded log data.
1) Select [LOGGER] with the multi-selector and determine with
the Enter operation.
2) Select [LOG D
AT
A] and determine with the Enter operation.
3) Select the saved log data with the multi-selector.
When Enter is being operated the menu is displayed.
Select the menu and determine with the Enter operation.
• VIEW D
AT
A: Reads the recorded log data and creates a graph.
• D
AT
A NAME: Edits the file names of the log data.
• EXPORT [.CSV]: Convers (the data?) to CVS format and saves
onto a micro SD card.
• PROJEC
T
: Protects and saves the log data.
• DELETE: Deletes the log data.
ENTER