V21 Parts & Service Manual
All V21 Identified Equipment
REV A – 10/2013
P/N: 1230298
If selection button two is pressed while “
SL X
” is displayed, the display will change to “
C0 1
”.
Pressing selection button one will increase or decrease the column number displayed. Pressing
selection button two will actuate the changed connection status of the column number
displayed. If the column number is flashing it is assigned to the selection that was entered. If the
column number is steady, it is not assigned to the selection button. To exit this mode, press
selection button three to display “SAVE”, then press selection 2 to confirm save.
EnrG
Energy Management Mode
If selection button two is pressed at "EnrG" prompt , the controller will enter the Energy
Management Mode.
Available Options:
Each option will have its specific operational hours during which the EMS system will control the
illumination and refrigeration system to achieve maximum energy efficiency.
EP 0
: Disable Energy otions
EP 1
: Facilities where operating hours are between 6 am till 9 pm ( ex.Manufacturing facilities )
EP 2
: Facilities where operating hours are between 7 am till 3 pm ( ex corporate / Schools )
EP 3
: Facilities where operating hours are between 9 am till 9 pm ( ex Retail Stores )
St
: 0,1,5,30 : If a sensor is present, this is the time the light will turn off after an inactivity period.
Please note : Activation of Clock is required - Please refer to Clock Setting in this manual.
SET-UP AND CODE DESCRIPTION (CONTINUED)
Cddr
Closed Door Data Retrieval Mode
If selection button two is pressed at the “
Cddr
” prompt, the controller will enter the Closed
Door Data Retrieval Mode by displaying “
XXXX
” where “
XXXX
” is the password. Pressing
selection button number one while the digits are flashing will change the current password. The
available digits are 0-6. (
See note below
.) Pressing selection button two will save the change
and advance to the next digit. In order to save the password and exit the mode, press selection
button two while the last/fourth digit is flashing.
Note:
If one of the digits in the password is “0” this feature will be disabled since selection button
“0” does not exist.
Note:
This feature is not available when the vend price is set to “0.00”.
LAnG
Language Mode
If selection button two is pressed at the “
LAnG
” prompt, the controller will enter the Language
Mode by displaying the currently assigned language. The available languages are
EnG
–
English,
Frn
– French,
GEr
– German,
ItA
– Italian,
Port
– Portuguese, and
ESP
– Spanish.
V21
12.1 Programming Trade | P3-10