Alignment & Troubleshooting
Service Manual
4-76
Samsung Electronics
Code
Displayed Name
Meaning
State
Displayed
08-800 Bypass Feed Clutch
Engages drive to pick up a paper from bypass.
On[Off]
08-810 T1 Pick-Up Clutch
Engages drive to pick up a paper from tray1.
On[Off]
08-820 T2 Pick-Up Clutch
Engages drive to pick up a paper from tray2. (Optional)
On[Off]
08-830 T3 Pick-Up Clutch
Engages drive to pick up a paper from tray3. (Optional)
On[Off]
08-840 T4 Pick-Up Clutch
Engages drive to pick up a paper from tray4. (Optional)
On[Off]
08-850 Registration Clutch
Engages drive to registartion rolls.
On[Off]
08-860 Duplex Feed Clutch
Engages drive to feed a paper into duplex path.
On[Off]
08-870 Duplex Gate Clutch
Engages drive to ready a paper into duplex path.
On[Off]
08-920 T2 Feed Motor Run
T2 Feed Motor On/Off
On[Off]
08-930 T3 Feed Motor Run
T3 Feed Motor On/Off
On[Off]
08-940 T4 Feed Motor Run
T4 Feed Motor On/Off
On[Off]
7) Developer
Code
Displayed Name
Meaning
State
Displayed
09-100 MHV Bias
MHV bias voltage on at normal drive level
On[Off]
09-110 MHV Bias Read
Detect what the MHV value is on the MHV Roller
Numeric 3 digits
09-200 Dev Bias
Dev bias voltage on at normal drive level
On[Off]
09-300 THV(+) Bias
THV plus bias voltage on at normal drive level
On[Off]
09-310 THV Bias Read
Detect what the THV value is on the THV Roller
Numeric 3 digits
09-400 THV(-)Bias
THV minus bias voltage on at normal drive level
On[Off]
09-500 SMPS Fan Run
Start/Stop Deve. Fan run
On[Off]
09-510 SMPS Fan Run Ready
Detects if Deve Fan runs at normal speed.
High[Low]
09-600 Toner Dispense Motor
Toner Dispense Motor On/Off
On[Off]
09-700 Toner Sensor
TC sensor in developer tank.
Numeric 3 digits
09-800 Detach Bias
Detach bias voltage on at normal drive level
On[Off]
8) Fuser
Code
Displayed Name
Meaning
State
Displayed
10-100 Fuser Power On
It controls temperature of fuser as 180 degrees.
On[Off]
10-200 Fuser Temperature A
Detects what the temperature A is on fuser.
Numeric 3 digits
10-210 Fuser Temperature B
Detects what the temperature B is on fuser.
Numeric 3 digits
10-300 Fuser Unit Fault
Detects if the IH board for controling fuser is normal.
Normal/Fault
10-400 Fuser Motor Forward
Fuser Motor Forward On/Off
On[Off]
10-500 Fuser Fan Run
Start/Stop Fuser Fan run
On[Off]
10-600 Fuser Bias
Fuser bias voltage on at normal drive level
On[Off]
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA