1.7 Connecting
to
a Door Phone and a Door Lock
Connect a door phone and a door lock to the OfficeServ 7200 system by using a
Door Phone Interface Module(DPIM).
1) Connect a pair of #24 AWG or #26 AWG cables to the LINE port of DPIM and
to P1 through P8 of 8DLI/16DLI/8COMBO Modules of the OfficeServ 7200
system.
Connecting to the 8DLI Module
Pin No.
1
2
3
4
5
6
7
8
Function -
-
-
DLI
TIP DLI
RING -
-
-
Figure 7.10 RJ-45 Port of 8DLI Module (For Door Phone)
Connecting to the 16DLI Module
Pin No.
1
2
3
4
5
6
7
8
Function -
-
-
DLI
TIP DLI
RING -
-
-
Figure 7.11 RJ-45 Port of 16DLI (For Door Phone)
Connecting to the 8COMBO
Pin No.
1
2
3
4
5
6
7
8
Function -
-
-
DLI
TIP DLI
RING -
-
-
Figure 7.12 RJ-45 Port of 8HYB Module (For Door Phone)
2) Connect the Door Box port of the DPIM to the Line port of the door phone.
P1 ~ P8
(RJ-45)
P1 ~ P8
(RJ-45)
P1 ~ P8