Connecting to the 16DLI Module
Connect a digital phone to the 16DLI Module by using a pair AWG #24 or AWG
#26 cables.
Pin No.
1
2
3
4
5
6
7
8
Function -
-
- DLI
TIP
DLI
RING -
-
-
Figure 7.5 RJ-45 Port of the 16DLI Module (For Digital Phone)
Connecting to the 8COMBO Module
Connect a digital phone to the 8COMBO Module by using a pair AWG #24 or
AWG #26 cables.
Pin No.
1
2
3
4
5
6
7
8
Function -
-
- DLI
TIP
DLI
RING -
-
-
Figure 7.6 RJ-45 Port of the 8COMBO Module (For Digital Phone)
Maximum number of DS-5012L phones connectable
Up to eight DS-5012L phones can be connected to each DLI Module(8DLI/16DLI)
of the OfficeServ 7200 system. If nine or more DS-5012L phones are connected to
the DLI Module, the power provided to all digital phones connected to the same
Module is turned off automatically. Up to 24 DS-5012L phones can be connected to
the basic Chassis or the expansion Chassis.