CHAPTER 7
© SAMSUNG Electronics Co., Ltd.
Page 7-1
Connecting Stations and Additional
Equipment
This chapter describes how to connect various stations and additional equipment,
such as analog/digital phones, door phones and door locks, to the OfficeServ 7200
system.
1 Connecting Stations
1.1
Cautions for Connecting Stations
Take the following cautions when connecting stations.
y
Do not connect stations in weather conditions such as storm and lightning.
y
Do not connect stations in a humid area.
y
Comply with the manual of the station and with this document when reconnecting
stations or changing connections.
y
Connect stations to a pair of #24 AWG or #26 AWG cables.
The distances between stations and the OfficeServ 7200 system are as follows:
Table 7.1 Distance Between Stations and the System
Station
Distance
Digital phone
Maximum 400 m(for AWG #24)
Analog phone
Maximum 1 km(for AWG #24)
Door phone
Maximum 400 m(for AWG #24)
AOM
Maximum 400 m(for AWG #24)
WBS24
Maximum 600 m(0.64 twisted cable)
Maximum 400 m(0.40 twisted cable)