CHAPTER 7. Connecting Stations and Additional Equipment
OfficeServ 7200 Installation Manual/Ed.00
Page 7-2
© SAMSUNG Electronics Co., Ltd.
1.2
Connecting an Analog Phone
Connect an analog phone to the 8SLI, 16SLI, 16MWSLI or 8COMBO Module
mounted on the OfficeServ 7200 system.
Connecting to the 8SLI Module
Connect an analog phone to the 8SLI Module by using a pair of AWG #24 or AWG
#26 cables.
Pin No.
1
2
3
4
5
6
7
8
Function
PFT TIP
PFT RING
-
SLI TIP
SLI RING
-
-
-
Figure 7.1 RJ-45 Port of the 8SLI Module
Connecting to the 16SLI and 16MWSLI Module
Connect an analog phone to the 16SLI and 16MWSLI Module by using a pair of
AWG #24 or AWG #26 cables.
P1 port
Pin No.
1
2
3
4
5
6
7
8
Function
PFT TIP
PFT RING
-
SLI TIP
SLI RING
-
Ports from P2 to P8
Pin No.
1
2
3
4
5
6
7
8
Function -
-
-
SLI
TIP
SLI
RING
-
Figure 7.2 RJ-45 Port of the 16SLI/16MWSLI Module
P1 ~ P8
(RJ-45)
P1~ P8
(RJ-45)