1.2.2 Inquiry of Config & Status
With the selected [Config & Status] menu, the established value and status regarding
the LAN and the WLAN can be inquired.
Figure 5.3 Web screen for inquiring the WBS24 status (Config & Status)
Status items are shown below.
Up-Time : the passed time after booting
Booting Time : the final time of WBS24 booting
Version : Information on the WBS24 version
DASL Status : Connection status with the 8WLI
−
Deactive : Not activated status of the DASL line
−
Active(Not Config) : DASL line is activated, and the initialized message is
not received from the system.
−
Active(Config OK) : DASL line is activated, and the initialized message is
received from the system.
B-channel Status : the number of traffics being in use at present
Associated Nodes : Unavailable at present