SAMSUNG DCS
PROGRAMMING
TECHNICAL MANUAL
SECTION
Page 46 of 280
DCS & DX I&M
August 2001
MMC 204:
Common Bell Control
DESCRIPTION:
Determines whether the common bell relay contacts have an interrupted or continuous closure when
activated. If interrupted is chosen, the relay follows an internal CO ring pattern of one second closed followed
by three seconds open.
As default, all common bell relay pairs are assigned as 380X DCS, 381 Comp, 36X DCS 70, 362 DCS24 &
DX408
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor
SPK
Used to store data and advance to next MMC
ACTION
DISPLAY
1.
Press TRSF 204
[3801] COM. BELL
Display shows current setting
CONTINUOUS
2.
Dial common bell number
[3802] COM. BELL
OR
CONTINUOUS
Press UP or DOWN key to make selection of
common bell numbers and press RIGHT
soft key to advance cursor
3.
Dial 0 for continuous or 1 for interrupted
[3802] COM. BELL
operation
INTERRUPTED
OR
Use UP or DOWN to scroll through options
Press RIGHT soft key to return to step 2
above
4.
Press TRSF to store and exit
OR
Press SPK to store and advance to next
MMC
DEFAULT DATA:
CONTINUOUS
RELATED ITEMS:
MMC 203 ASSIGN UA DEVICE
MMC 601 ASSIGN STATION GROUP
DCS200 Version 6.x, DCS70,DCS24 &DX408 RELATED ITEM:
MMC 219 COMMON RELAY SERVICE TYPE
Note:
There is only one common bell circuit per Trunk A card. A second Trunk A
card would need to be installed for 3802 to be valid.