MMC 606:
Assign Speed Block
DESCRIPTION:
Provide a means of adding or deleting speed dial blocks to the system or an individual keyset. With the ability
to delete a block or blocks of speed dial memory, it will not be necessary to waste blocks on such items as
voice mail, SIMs, DPIMs or for stations that do not require the ability to use speed dial.
The Free List will show how many bins are left to be assigned. One block has a ten (10) entries. DCS has a
1500 entries maximum per system, 500 for System Speed and up to 50 on a per station maximum. The DCS
70 and DCS Compact have a maximum of 600 and 500 entries respectively, with a maximum of 500 for
System Speed and 50 maximum per station. Accordingly, if the System Speed block has been assigned as
500 entries then 1000 entries on DCS, 100 on the DCS 70 and 0 on the DCS Compact can be shared by all
extensions. DCS 24 has a maximum of 500 entries in a system: 300 for System Speed, while the rest can be
allocated as personal numbers with a maximum of 50 per–station. For example, if the System Speed block
has been assigned as 100 entries then 100 entries can be shared between the extensions. DX408 has a
maximum of 300 per system.
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor left and right
SPEAKER
Used to store data and advance to next MMC
HOLD
Used to clear entry
TRSF
To exit programming
ACTION
DISPLAY
1.
Press TRSF 606
FREE LIST:60
Display shows
SYSTEM:20
2.
Press RIGHT soft key to advance cursor to next line
FREE LIST:60
SYSTEM:20
3.
Make a selection of SYSTEM or EXT using UP or
FREE LIST:60
DOWN key and press RIGHT soft key to advance cursor
EXT201:1
4.
Enter desired EXT number via dial key pad (eg., 205)
FREE LIST:60
OR
EXT205:1
Press UP or DOWN key to make selection and press
RIGHT soft key to advance cursor
5.
Enter in valid number for bins (eg., 0–5 for EXT or
BUSY LIST:60
00–50 for SYSTEM)
EXT205:5
OR
Press UP or DOWN key to make selection
OR
Press HOLD key to delete bin(s)
6.
Press TRSF to store and exit
OR
Press SPK to store and advance to next MMC