SAMSUNG DCS
PROGRAMMING
TECHNICAL MANUAL
SECTION
Page 110 of 287
Updated I&M
May 2002
MMC 412:
Assign Trunk Signal
DESCRIPTION:
Used for programming the type of signalling when E&M tieline cards are installed. DCS200 & DCS70 only.
The type of signalling used must be identical for the equipment at both ends of the E&M link. For example
the DCS200 E&M card and the router.
The signalling condition types are as follows:
CONDITIONS
IMMEDIATE
DELAYED
WINK
IMMEDIATE
DELAYED
WINK
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor left and right
SPK
Used to store data and advance to next MMC
ANS/RLS
Used to select ALL
ACTION
DISPLAY
1.
Press TRSF 412
[701]
TRK
SIGNAL
Display shows
IMMEDIATE START
2a.
Enter desired trunk number (eg., 704)
[704]
TRK
SIGNAL
OR
IMMEDIATE START
Press UP or DOWN key to make selection
and press RIGHT soft key to move cursor
OR
Press ANS/RLS to select all trunks
2b.
Enter desired trunk type selection from
[704]
TRK
SIGNAL
above list
WINK
OR
Press UP or DOWN key to make selection
and press RIGHT soft key to
return to step 2a
3.
Press TRSF to store and exit
OR
Press SPK to store and advance to next
MMC
DEFAULT DATA:
None
RELATED ITEMS:
MMC 714 DID Number and Name Translation