Safety information and precautions
Specification of SN200G high-performance vector convertor
- 2 -
Introduction
General functions and descriptions of SN200G series frequency convertor:
1
)
Abundant voltage classes: support three voltage classes, namely single-phase 220V, three-phase
220Vand three-phase 380V.
2
)
Abundant control mode: apart from vector control of velocity sensor, sensorless vector
control and V/F control, support V/F separation control.
3
)
Abundant field bus: support Modbus-RTU and CANlink field bus.
4
)
Abundant encoder types: support difference encoder, open collector encoder and rotary
transformer, etc.
5
)
Brand-new sensorless vector control algorithm
Brand-new SVC creates better low-velocity stability, stronger low-frequency load capacity, and
supports torque control of SVC.
6
)
Powerful background software: uploading, downloading parameters, real-time oscilloscope can be
realized on background software.
Functions
Descriptions
Overheat protection of motor After choosing SN200GPC1 expansion card, AI3 can receive temperature
sensor input of motor (PT100, PT1000) to realize overheat protection
Fast current limiting
Avoid over-current fault of frequency convertor
Dual motor switch
Two sets of motor parameters can realize dual motor switch
Restore user parameters
Users can save or restore own parameter settings
Accurate AIAO
After factory calibration (or spot calibration), AIAO accuracy can be<20mv
Show customized parameters Users can customize function parameters to be displayed
Show altered parameters
User can view function parameters after modification
Optional fault handing ways Users can select action modes of convertor after confirming certain faults:
free halting, deceleration halting, continual operation. The users can also
select frequency for continual operation.
PID parameter switch
Two sets of PID parameters can switch by terminal or based on deviation
PID feedback loss detection PID feedback loss detection value realizes protection during PID operation
DIDO positive/negative logic Users can set positive/negative logic of DIDO
DIDO response delay
Users can set response delay time of DIDO
Run under instantaneous stop Frequency convertor continues running within short time if instantaneous power
outage or voltage decrease
Timing operation
Support timing operation for 6,500 minutes at most
Opening for inspection:
When opening the box, please carefully confirm if the nameplate model and rated value of frequency
convertor are consistent with order. The package contains ordered machine, qualification certificate,
operation manual and warranty bill.
If any damage during transportation or certain omission, please contact with our company or supplier.