Specification of SN200G high-performance vector convertor
Product information
- 12 -
Items
Specifications
Individu
alized
functions
Excellent performance
Realize motor control with high-performance current vector control
Operate under instantaneous
stop
Offset reduced voltage through load feedback energy if
instantaneous outage, keep continual operation of frequency
convertor within short time
Fast current limiting
Avoid frequent over-current fault of frequency convertor
Timing control
Timing control function: set time range 0.0Min
~
6500.0Min
Multi-motor switch
2 sets of motor parameters realize switch control of 2 motors
Multi-threading bus
Support two kinds of spot field bus: RS-485, CANlink
Overheating protection
Optional multi-function card, analog input A13 can receive motor
temperature sensor input (PT100, PT1000)
Multi encoder
Support various encoders such as differentiation, open collector and
rotary transformer
Programmable by users
Optional user programmable card realizes secondary development
Powerful background
software
Support parameter operation and virtual oscilloscope
function. Realize graphic monitoring of internal status of
frequency convertor through virtual oscilloscope
Operation
Command source
Given operation panel, given control terminal, given
serial communication port. Switch through multiple
ways
Frequency source
10 frequency sources: given digit, given analog voltage, given
analog current, given pulse, given serial port. Switch through
multiple ways
Auxiliary frequency source 10 auxiliary frequency sources. Realize auxiliary frequency trimming
and frequency synthesis flexibly
Input terminals
Standard:
5 digital input terminals, in which 1 terminal supports high-speed
impulse input at100Hz
2 analog input terminals, in which 1 supports voltage input at 0
~
10V, 1
supports voltage support at 0
~
10V or current input at 4
~
20mA
Expansion capability:
5 digital input terminals
1 analog input terminal supports voltage support at 0
~
10V
Output terminals
Standard:
1 high-speed pulse output terminal (open collector is optional), support
square signal output at 0~100kHz
1 digital output terminal
1 relay output terminal
1 analog output terminal supports current input at 0
~
20mA or voltage
support at 0
~
10V
Expansion capability:
1 digital output terminal
1 relay output terminal
1 analog output terminal supports current input at 0
~
20mA or voltage
support at 0
~
10V