Specification of SN200G high-performance vector convertor
Parameter description
- 141 -
A2-05
rated speed
Factory default
Model determination
Setting range
1rpm
~
65535rpm
A2-06
Induction motor stator resistance
Factory default
Model determination
Setting range
0.001Ω
~
65.535Ω(frequency converter power <=55kW)
0.0001Ω
~
6.5535Ω(frequency converter power >55kW)
A2-07
Rotor resistance of induction motor
Factory default
Model determination
Setting range
0.001Ω
~
65.535Ω(frequency converter power <=55kW)
0.0001Ω
~
6.5535Ω(frequency converter power >55kW)
A2-08
The leakage inductance of
asynchronous motor
Factory default
Model determination
Setting range
0.01mH
~
655.35mH(frequency converter power <=55kW)
0.001mH
~
65.535mH(frequency converter power >55kW)
A2-09
Induction motor mutual inductance
Factory default
Model determination
Setting range
0.1mH
~
6553.5mH(frequency converter power <=55kW)
0.01mH
~
655.35mH(frequency converter power >55kW)
A2-10
No-load current of induction motor
Factory default
Model determination
Setting range
0.01A
~
A2-03(frequency converter power <=55kW)
0.1A
~
A2-03(frequency converter power >55kW)
A2-27
Encoder line number
Factory default
1024
Setting range
1
~
65535
A2-28
Speed fbk sel
Factory default
0
Setting range
0
ABZ incremental encoder
1
Retention
2
Rotating transformer
A2-29
Speed feedback PG selection
Factory default
0
Setting range
0
Local PG
1
Extension PG
2
PULSE pulse input (DI5)
A2-30
ABZ incremental encoder AB
sequence
Factory default
0
Setting range
0
forward direction
1
reverse
A2-34
Pole pairs of rotating transformer
Factory default
1
Setting range
1
~
65535
A2-36
Speed feedback PG disconnection
detection time
Factory default
0.0s
Setting range
0.0
:
failure to actuate
0.1s
~
10.0s