Specification of SN200G high-performance vector convertor
Parameter description
- 147 -
A6-28
AI3 sets jump point
Factory default
0.0%
Setting range
-100.0%
~
100.0%
A6-29
AI3 sets jump range
Factory default
0.5%
Setting range
0.0%
~
100.0%
SN200G analog input AI1 ~ AI3, possess setpoint skip function.
Skip function means that when a corresponding analog set point jump up and down when the
interval changes, the analog value corresponding to the set point value is fixed at the jump.
Example: Analog input AI1 voltage at 5.00V fluctuations, fluctuation in the range of 4.90V ~ 5.10V,
AI1 minimum input 0.00V corresponds to 0.0%, the maximum input 10.00V corresponds to 100.%, then
detected the corresponding setting AI1 between 49.0% ~ 51.0% volatility.
Setting AI1 setting jump points A6-24 50.0%, set AI1 setting A6-25 jump amplitude of 1.0%, and
then the above AI1 input, after the jump function to give the corresponding input of AI1 setting is fixed at
50.0% AI1 is converted into a stable input, eliminating fluctuations.
A7 group--User-programmable functions
See
User-programmable controller card
Supplementary Manual.
AC group: AIAO calibration
AC-00
AI1 measured voltage 1
Factory default
Calibration
Setting range
0.500V
~
4.000V
AC-01
AI1 display voltage 1
Factory default
Calibration
Setting range
0.500V
~
4.000V
AC-02
AI1 measured voltage 2
Factory default
Calibration
Setting range
6.000V
~
9.999V
AC-03
AI1 display voltage 2
Factory default
Calibration
Setting range
6.000V
~
9.999V
AC-04
AI2 measured voltage 1
Factory default
Calibration
Setting range
0.500V
~
4.000V
AC-05
AI2 display voltage 1
Factory default
Calibration
Setting range
0.500V
~
4.000V
AC-06
AI2 measured voltage 2
Factorydefault
Calibration
Setting range
6.000V
~
9.999V
AC-07
AI2 display voltage 2
Factory default
Setting range
-9.999V
~
10.000V
AC-08
AI3 measured voltage 1
Factory default
Setting range
-9.999V
~
10.000V
AC-09
AI3 display voltage 1
Factory default
Setting range
-9.999V
~
10.000V