4-29
3
2
4-5 LINEAR ENCODER SETUP (Referential Time : 5min.)
This is for checking the reading of the linear encoder and for calibrating its expansion/contraction caused by the op-
eration environment. This operation is required when Limit Sensor, Encoder Scale or Encoder Module is replaced or
the position is adjusted.
Make sure to unload the media.
Lower the Pinch Rollers.
Also, be sure to remove the Media Clamps.
Select [PRINT MENU]>[LINEAR ENCODER], and press [EN-
TER] key.
Turn on the Sub Power SW while pressing [ ], [ ] and
[ ] keys to enter the Service Mode.
1
PRINT MENU
LINEAR ENCODER
NOW PROCESSING..
POS: 1361.00mm
SERVICE MENU
PRINT MENU
[ ] [ ]
[ ]
MENU
SERVICE MENU
+
MENU
Summary of Contents for VS-300
Page 49: ...2 4 MAIN BOARD_Arrangement Diagram Soldering Side ...
Page 60: ...2 15 SERVO BOARD_Arrangement Diagram Soldering Side ...
Page 65: ...2 20 2 4 CARRIAGE BOARD CARRIAGE BOARD_Arrangement Diagram Component Side ...
Page 68: ...2 23 2 5 SUB BOARD SUB BOARD_Arrangement Diagram Component Side ...