39
7 Operation Guide [Scanning Section]
Remove the screws shown in the figure and detach the
work plate.
Orient so the surface with the grid faces up.
Mount the object to be scanned.
Secure the object to be scanned in place on the work plate for scanning.
Mount the object to scan securely in place so that it does not move during scanning.
The grid on the table serves as a guide for mounting the object to scan. It does not indicate the scanning
area for Dr. PICZA. The scale is in 10 mm (3/8 in.) units.
Maximum scanning area of the MODELA
The maximum scanning area is shown in the figure.
MDX-20 : 203.2 mm (8 in.)
MDX-15 : 152.4 mm (6 in.)
MDX-20 : 152.4 mm (6 in.)
MDX-15 : 101.6 mm (4 in.)
Maximum scaning area
1 mm (0.0394 in.)
60.5 mm (2-3/8 in.)
Work plate
* This space cannot be scanned.
When the shape has a flat bottom
and is easy to secure in place
When the bottom is uneven and difficult to secure
in place
When scanning as far as the bottom surface of
the object to be scanned
Secure in place with
double-sided tape.
Make a base using clay, and press
the object into the clay base from
above to secure it in place.