7
DALIS
Digital electric unvented heat pump
Description
Unit of
measure
Dalis
200DHW4
Dalis
200DHWI4
Dalis
260DHW4
Dalis
260DHWI4
Electrical data
Power supply
V
1/N/230
Frequency
Hz
50
Degree of protection
-
IPX4
Max. absorption
kW
0.50
Average power absorption
kW
0.37
Heating e max. absorption
kW
2
Power
kW
1.5
Max. current
A
2.3
Overload protection
A
16A T fuse / 16A automatic switch, characteristic C
(to be expected during installation on power supply
systems
Internal protection
-
Single safety thermostat with manual reset
Functions
Temperature min. ÷ max. air intake 90% R.H.
°C
4 ÷ 43
Min. ÷ max temperature installation site
°C
4 ÷ 43
Working temperature
Max. programmable temperature - ECO
°C
56
Max. programmable temperature - AUTO
°C
70
Compressor (rotary) & fan (centrifugal)
Compressor protection
-
Thermal circuit breaker with automatic reset
Ejection outlet diameter
mm
160
Revolutions per minute
RPM
1,420
Nominal air capacity
m
3
/h
350
Max. pressure head available
Pa
100
Motor protection
-
Internal thermal circuit breaker with automatic reset
Condenser
Wrapped externally, not in contact with water
Refrigerant R134a (load)
g
900
Water storage
Capacity
litres
200
260
Actual water storage capacity Vm
litres
199
194
254
246
Max. volume hot water Vmax (3)
litres
276
342
Connection coil solar thermal power system
m2
n/a
0.9 m
2
n/a
0.9 m
2
Cathodic protection
mm
2 x Mg anode Ø33 x 250; G1 1/4”
Insulation
-
50mm high density polyurethane foam
Defrosting
-
Passive with air
Empty weight / when filled with water
Kg
81 / 280
92 / 286
93 / 347
110 / 356
Sound power indoors Lw(A)
(4)
dB (A)
59
Automatic anti-legionella cycle
(5)
-
YES
Maximum working pressure
bar
7
(1) temperature of incoming air supply 20°C (max.15°C), temperature of water heater storage environment 20°C, water heated from
10°C to 55°C, (according to EN 16147-2011). (2) measurements carried out according to EN 12897-2006. (3) measurements carried
out according to EN 16147-2011. (4) measurements carried out according to EN 12102-2013. (5) Automatic activation - 30 day cycle.
Summary of Contents for Dalis 200DHW4
Page 46: ......