27
DALIS
Digital electric unvented heat pump
•
ECONOMY mode
This mode only uses the renewable energy of the heat pump without activating the electric heating
elements. It takes longer to enable but has considerable energy saving characteristics.
•
OVERBOOST mode
This mode heats the water quickly by the using both the heat pump and the electric heating elements.
This function can be activated manually when the water temperature in the tank is below 40°C. At the
end of the heating process, the function is automatically disabled and the product is automatically
reset to AUTOMATIC or ECONOMY mode depending on which of these two functions was previously
programmed.
•
ANTI-LEGIONELLA mode
This function is used as an antibacterial treatment to eliminate harmful bacteria by increasing the
water temperature to 60ºC. This function is activated automatically every 30 days, regardless of the
current mode in use.
•
DEFROSTING mode
This function is necessary in order to eliminate frost deposits, which prevent the transfer of heat. This
function is enabled automatically when the device is used at low ambient temperatures.
IMPORTANT
When the equipment is turned on for the first time, it is programmed by the manufac-
turer to operate in the economy mode, with a water temperature value of 55°C. This
ensures energy saving using the renewable energy sources of the heat pump only.
Please note that the use of this function enables the user to save an average energy
saving of approximately 70% compared to other standard electric water heaters.
10.4. Basic management
10.4.1. Switch on/off manually
Press the
button. The on/stand-by LED light will switch on/off. The equipment can also be
switched on / off during certain time slots; see parameters HOn and HOf.
If switching on/off manually, this always has priority over programmed time intervals.
If the keypad has been locked or an advanced function is in progress, it will not be possible to switch
the product on/off.
Each time the product is turned on, a series of internal inspections will be carried out before activating
the heat pump. The compressor indicator light
will blink as these inspections take place. Once
the verification period has passed (approximately 5 minutes), the indicator will remain lit meaning the
unit is on.
10.4.2. Setting the day and time
To set the day and time:
Summary of Contents for Dalis 200DHW4