8.12. Drain valve
We recommend a drain valve is installed (not supplied) in the lowest point of the cold water feed to
the product. This allows the product to be drained in a controlled manner if necessary (see figure 5).
8.13. Condensation drain connections
Condensation formed during operation of the heat pump should flow through a purpose-built outlet
pipe (G 1/2”) that passes inside the insulating casing and emerges on the side of the appliance.
Connect it to a duct via a siphon so that the condensation should flow as it should.
Figure 13a - example of condensation discharge Figure 13b - example of condensation
pipe connection via a siphon
discharge pipe connection via siphon
with
a
water
shut-off
valve
8.14. Electrical fittings
The product is supplied already wired for the mains power supply. It is powered through a flexible
cable and a socket/plug combination (figure 14). An earthed Type G socket (UK) with separate pro-
tection is needed for the connection to the mains power supply.
Figure 14 - type G socket and plug