MobiLink IP
Status indicators
MobilinkIP_Usermanual-sw1.2.21_revGen.doc
Page 29 of 188
6.2.2
Connecting to the MobiLink
Enter the IP address of the MobiLinkIP device (by default
192.168.173.1
) in the list of exceptions for
the Proxy server: “Do not use proxy server for addresses beginning with …”
To configure the MobiLink IP product using the web
interface, just open a favorite web browser and type the
default IP address as the URL:
https://192.168.173.1
Remember that the default gateway used by MobiLink IP has the IP address of
192.168.173.2.
If connecting to the MobiLinkIP equipment is not possible because of problems in the settings of the
IP address, go back to the factory default settings. Press the “RESET” button for at least three
seconds. The equipment reboots and starts operating with
the factory default settings
.
These include the IP address 192.168.173.1, allowing you to connect to the Rohde & Schwarz Topex
S.A. VoIP2Mobile in order to configure it. After reaching the configuration web pages, one may
change the IP address of the device according to personal requirements.
For instance, you can use addresses in the range
https://172.27.168.xxx/
or
https://10.0.0.1
, as shown in this
example:
Hardware Reset
To perform such a hardware reset to factory defaults, you must follow the procedure described
next, simply pressing the recessed RST button won’t work. So you must follow these steps:
-
shut down the MobiLinkIP device (unplug the power jack)
-
press the RST button and keep it pressed
-
power up MobiLinkIP
-
wait until all three LEDs light up in red, as shown in the picture below, and then leave the RST
button.
Now the equipment performs a reset with return to factory default settings.
This does NOT happen if you don’t follow exactly the procedure described above – for instance, if you
continue to press down the RST button after the three indicators have turned on in red color!