MobiLink IP
TECHNICAL SPECIFICATIONS
MobilinkIP_Usermanual-sw1.2.21_revGen.doc
Page 180 of 188
7. TECHNICAL SPECIFICATIONS
TITLE
DESCRIPTION
Mobile networks
supported
GSM /GPRS and respectively UMTS/HSPA for the 3G modules
Frequency bands
Depending upon actual type of modules fitted
GSM/GPRS/EDGE: Tri-band, 800/900/1800 MHz
UMTS 2100MHz: 2100 MHz (Band Class 1)
Supported
protocols
TCP/IP, PPP, CHAP, PAP, ARP, UDP, NTP and others
VoIP
Two channels, H323 and SIP protocols supported
Features
Secure Web page configuration, by means of a browser, no additional
software is required for administration and management
Wired
Network
interface
One LAN port, Ethernet 10/100 base-T
Connector type: female RJ45
Transfer speed: 10/100 Mbps
RTC
Optional Real Time Clock with holding Li-ion battery, keeps accurate
time even when the equipment is powered off.
Max. transmitter
power
Depending upon actual type of modules fitted
GSM/GPRS/EDGE 800/900MHz: +32dBm (Power Class 4)
GSM/GPRS/EDGE 1800MHz: +29 dBm (Power Class 1)
UMTS/HSDPA 2100MHz: +23dBm (Power Class 3. 8PSK mode Class
E2) , only for devices fitted with 3G modules
Receiver
static
sensitivity
Depending upon actual type of modules fitted
GSM/GPRS/EDGE 800/900: - 107 dBm
1800 MHz: -105 dBm
Compliant with TS 05.05 (R99)
UMTS/HSDPA 2100MHz: Compliant with 3GPP TS 25.101(R5) only
for devices fitted with 3G modules
Voice service
GSM: FR, EFR, HR, AMR
UMTS:
AMR(12.2kbps/10.2kbps/7.95kbps/7.4kbps/6.7kbps/5.9kbps
/5.15kbps/4.75kbps)
Concurrent
service (Based on
UMTS)
1 UMTS CS voice + 1 UMTS PS data, only for devices fitted with 3G
modules
SMS
Supporting SMS based on CS domain of GSM or UMTS Supporting
SMS based on PS domain of UMTS
Supply voltage
12 V
D.C
. (+ centre wire, - external conductor)
Mobile antennas
External quad-band antennas with magnetic base and cable
Supply adapter
Special adapter, Sunny Enterprises SYS135x
output : 12 V
D.C
. / 2 A
Input: from 100 to 240 V
A.C
. / 0,3 A / 50 Hz
Power
consumption
Less than 20 W
Status
indicators
Three bicolor LEDs, for Status, Mobile 1, Mobile 2
Temp. range
Operating: 5
0
.... 50
0
C
Storage: 0
0
.... 60
0
C