MobiLink IP
CALL CONTROL
MobilinkIP_Usermanual-sw1.2.21_revGen.doc
Page 154 of 188
Hardware factory defaults
“Return to Defaults” can also be performed via
hardware
. This means the Web interface doesn’t have
to be used.
For this, perform the Hardware reset described previously:
Remember, you must follow the procedure described next, simply pressing the recessed RST button
once, or keeping it depressed for a very long time won’t work!
So you must follow these steps:
-
shut down the MobiLinkIP device (unplug the power jack)
-
press the RST button and keep it pressed
-
power up MobiLinkIP
-
wait until all three LEDs light up in red color , then leave the RST button.
Now the equipment performs a reset with return to factory default settings.
This does NOT happed if you don’t follow exactly the procedure described above – for instance, if you
continue to press RST after the three indicators have turned on in red color!
This way of restoring the factory default settings is faster than using the web interface, but the same
care should be exercised.
Note
: T
he “Return to Defaults” option is quite useful when incorrect settings have been performed or
when the IP of the MobiLinkIP device are forgotten. If not having the IP address or if having incorrect
settings for iptables, one won’t be able to connect to the VoIP2Mobile to administer it.
Perform a hardware “factory defaults”, and MobiLinkIP will revert to its original settings, including the
IP address of 192.168.173.1