Page 1: ...MobiLink IP VoIP GSM Gateway User Manual 2012...

Page 2: ...circuit is write protected being dedicated for the operating system kernel The other flash circuit is for the applications which can be easily updated upgraded or enhanced High security Configurable s...

Page 3: ...MobiLink IP MobilinkIP_Usermanual sw1 2 21_revGen doc Page 3 of 188 Conformity...

Page 4: ...t shall not be recycled as household waste it will be disposed separately as sorted waste At the end of its life it will be given to a specialized recycle firm Please do not dispose of this product as...

Page 5: ...F DESCRIPTION MADE BY A E 2009 2011 All A M First issue and different changes C Malide V Sfetcu F 2012 Cover conformity A M Added conformity information V Sfetcu G May 2012 Update to firmware 1 2 21 a...

Page 6: ...ons for configuration 26 6 2 Using the web interface 26 6 2 1 Set up a connection 27 6 2 2 Connecting to the MobiLink 29 6 2 3 Log in 32 6 2 4 Dual log in 34 6 2 5 Menu Items 35 6 2 6 SMS Pages log in...

Page 7: ...s Definition 130 6 9 4 Mobile Users Definition 131 6 9 5 Dynamic Call Routing and Call back CBK Operation 133 6 9 6 Trunk or User 134 6 10 SYSTEM 135 6 10 1 Status 136 6 10 2 Syslog View 138 6 10 3 Sy...

Page 8: ...ink devices connected analogue FXO FXS or digital ISDN NT TE phone ports to mobile networks this one has a Voice over IP port since it was designed to convert outgoing and incoming calls from VoIP to...

Page 9: ...all tasks of operation administration and management via Web interface Intended use MobiLink IP was also intended to be a complimentary product for the line of Class 4 Class 5 Rohde Schwarz Topex S A...

Page 10: ...plastic case It is a mobile gateway that terminates VoIP calls which least call routing for SIP calls Power supply switching mains adapter Input 100 240V A C Output 12VD C 2A Max Power 25 W Ethernet...

Page 11: ...e that shows up in the browser allows easy access to all its settings Since the product is Linux based applications to enhance MobiLinkIP or to customize it according to the special needs of various c...

Page 12: ...this code when you call Support for upgrade and for repairs PRODUCT IMEI LABEL IMEI code International Mobile Equipment Identity for SIM based equipments An unique 15 or 17 digit number If the Topex d...

Page 13: ...nd for repairs Also when you perform software upgrade you must check that the firmware version you want to load is fitted for your model of equipment For this the first letters must be the same if you...

Page 14: ...ersion actually running on it For this you must access the System Status page Just enter into the browser the URL for the page https 192 168 173 1 System Status The information about serial number cur...

Page 15: ...Firmware version version of the application firmware running on MobiLinkIP you may see Mobililik ip 1 2 18 M2J SAX or Mobililik ip 1 2 21 M2J SCX The firmware can be easily updated a new version upgra...

Page 16: ...y the customer the label on the product remains the same although the application program is now different 5 1 ESTABLISHING THE BEST LOCATION In order to determine the best location for the ROHDE SCHW...

Page 17: ...the mounting kit plastic dowels woodscrews etc provided by Rohde Schwarz Topex S A On the back there are two pairs of mounting holes 160 mm apart The two pairs are located 100 mm from another to secur...

Page 18: ...Connectors of MobiLinkIP Towards the left edge the round connector is for the power supply jack labeled DC 12VDC The black Reset button recessed labeled RST To the right one female RJ45 connector for...

Page 19: ...ite end of the UTP cable can be inserted directly into a PC or in switches or hubs The STATUS indicator LED of the MobiLink case will light up showing physical connection and will blink to indicate da...

Page 20: ...the power supply adapter shipped in the equipment package Using other kinds of power supplies may cause damage to the equipment To avoid accidents or damage to the equipment follow the steps described...

Page 21: ...ore inserting the SIM card to avoid PUK locking Disable GSM services GSM operator offers different supplementary services for calls When using the MobiLinkIP interface it is recommended that these opt...

Page 22: ...ow the next steps WARNING Unplug the MobiLink IP unit from the main outlet before insert or replace a SIM card For each of the SIM cards follow these steps 1 Press the little button to eject the SIM h...

Page 23: ...ity of transmission and to reduce radio interference use the antennas shipped in the MobiLinkIP package These antennas were designed for the respective frequency bands multiband to allow proper connec...

Page 24: ...band stick antennas with magnetic base currently supplied with the MobiLink package Frequency bands GSM 890 960 MHz PCN 1710 1880 MHz PCS 1850 1990 MHz UMTS HDSPA 1920 2170 MHz Gain 2 dBi Polarizatio...

Page 25: ...t interface of MobiLinkIP Off device not powered no supply voltage On Red color no ETH network is connected On Orange color ETH port connected to the local network but no traffic Orange blinking ETH p...

Page 26: ...desktop PC or notebook may be connected to the Mobile 2 IP gateway either directly or through a hub by means of wired Ethernet connection Important Note Prior to using this VoIP to Mobile device you s...

Page 27: ...ion to be used for the MobiLinkIP gateway Use a significant name such as MobiLinkIP or VoIP2Mobile From the network adapters network cards select the one which is connected via Ethernet cable to the M...

Page 28: ...r 172 16 In this case you must first set you computer manually to the range of addresses that MobiLink IP can see then configure MobiLink for the requirements of your particular network and finally re...

Page 29: ...he IP address 192 168 173 1 allowing you to connect to the Rohde Schwarz Topex S A VoIP2Mobile in order to configure it After reaching the configuration web pages one may change the IP address of the...

Page 30: ...usual http so one may get several warning messages for example or similar warnings mentioning Website Certified by an Unknown Authority Click Yes OK or Accept to continue Type OK to accept the certif...

Page 31: ...ion to prevent hackers from capturing passwords and sensitive data which is the same security used by banks and the military or Internet Explorer shows the padlock icon only when everything on the ent...

Page 32: ...the MobiLink IP configuration page https 192 168 173 1 in order to log in with the user name that you want But if you have entered once in the web interface the passwords both for User and respective...

Page 33: ...n respectively When typing a different user name or if entering an incorrect password or when you press cancel the following error message will be displayed 401 Unauthorized Connect again and be caref...

Page 34: ...doc Page 34 of 188 6 2 4 Dual log in Depending on the link and user chosen you will see either the SMS Page when you log in as user or the administration pages if you log in as admin which of course...

Page 35: ...Voice over IP functions CALL CONTROL all settings related to the PBX application running on MobiLink IP which performs all the call management and control tasks REGISTER Settings for registration serv...

Page 36: ...page to be sure you see the latest values At the bottom of every Settings page you can see these three buttons The button Save is used to save the changes performed the Cancel button aborts the chang...

Page 37: ...can only send messages and see the received messages you don t have access to the Settings for SMS and email to SMS features Send To send out a text message simply enter the destination phone number...

Page 38: ...0 in case of non ASCII characters But you can send even longer text messages they will be broken into several consecutive SMS and sent one after another to the destination number The last box at the b...

Page 39: ...e a new record and Edit to modify it The first field is the name of the recipient of the message This name is meaningful for the human operator only MobiLink IP has no use for it The next field is the...

Page 40: ...V One if the links at the bottom of is Load CSV file You can use it to load a CSV comma separated value file previously created that holds the names telephone numbers and messages to be sent Such a fi...

Page 41: ...mat the zero 0 will NOT be taken into account if you create edit the CSV file in Notepad it must contain name destination phone number text of the SMS to be sent since the comma is the separator betwe...

Page 42: ...SMS list every line corresponds to a SMS message then press Send to send out all the messages Of course the transmission won t be simultaneous MobiLink IP sends out the messages one after another sta...

Page 43: ...particular case you must prepare a CSV file that contains only names and telephone numbers the text filed is empty To send out the same text message to several destinations load the CSV file with the...

Page 44: ...P_Usermanual sw1 2 21_revGen doc Page 44 of 188 In this window you can either enter the text by typing or paste it from a location where you copy the text of interest Use Save All button to save this...

Page 45: ...rmanual sw1 2 21_revGen doc Page 45 of 188 After a final review where you can edit or delete the current rows or add a new one press the button Send at the bottom of the list to send out the respectiv...

Page 46: ...nt up to seconds Also the time zone such as GMT 2 in case of Bucharest Remember this is not the time when the SMS was received by MobiLink IP but rather when it has been transmitted usually set by the...

Page 47: ...t get their common message they show the status OK Action In Outbox the field Action lets you Delete the SMS which have been sent or Resend them When a new session of sending out SMS messages they wil...

Page 48: ...k you for username and password admin 99admin11 log in as Admin Note Once authentication is done form a certain computer you don t need to do it again unless you restart the computer After logging in...

Page 49: ...ote user listed under HOME is admin When you log in to MobiLink IP as administrator username admin and corresponding default password 99admin 11 you have access to all the features and settings Rememb...

Page 50: ...This group features the pages of settings related to the local wired Ethernet network for IP routes for the NTP Client and respectively for the firewall IP tables 6 3 1 Status Each configuration subm...

Page 51: ...51 of 188 It this case it shows info about the state of the Ethernet interface and the current static routes Network Interface This is the detailed information about the Ethernet network interface of...

Page 52: ...e indicated by a digital point such as 0 5 in this case Adm0 0 0 2 The interfaces marked with a in their names are the Aliases see explanations further on that you have defined for the MobiLink IP equ...

Page 53: ...change the routes go to the section Routes of this page for defining and modifying routes The routes are shown from the top downwards from the most specific to the least specific Destination the desti...

Page 54: ...odified by a dynamic routing protocol R the route was re activated following update by dynamic routing protocol Routes may be configured as passive or static even when a protocol for dynamic routing i...

Page 55: ...network The default address value is 192 168 173 1 and the netmask is 255 255 255 0 One may change these default settings if the configuration of the network requires this for instance to 10 0 0 1 in...

Page 56: ...be used The Name Servers may be from the local network address 192 168 x y as the second entry in the following example or from the public network the great Internet such as 208 67 220 220 in the exam...

Page 57: ...or forwarding data packets This option page is concerned with defining fixed static routes It shows the current routing table for MobiLinkIP and allows defining several static routes The routes establ...

Page 58: ...P addresses Buttons Use New to create a new row route definition Edit to edit an existing definition Exit get out of the table and Save to save the changes Del erases from the table an existing route...

Page 59: ...S A devices If configuration changes were performed using the Save button is not enough since it saves the modifications only into the temporary memory of the MobiLinkIP Always press the Commit butto...

Page 60: ...h as utcnist colorado edu or ro pool ntp org The Current time indicator shows the current UTC time Universal Coordinated Time of the system with millisecond precision Notice there are two fields for T...

Page 61: ...the UTC time may be different from the local time of your computer To adjust this difference go to the configuration page SYSTEM Time And set the Time Zone accordingly When the NTP feature is enabled...

Page 62: ...nd changing the IP tables settings Here you can see the current state of data packets received and accepted Press the button Edit located at the bottom to go to the table with rules to perform changes...

Page 63: ...r decisions on the fate of packets and connections There are five predefined chains though a table may not have all chains Predefined chains have a policy for example ACCEPT which is applied to the pa...

Page 64: ...hen you change the type of protocol to be used for the Web interface of MobiLink IP you must use Commit then enter in the browser the new kind of address such as http 192 168 173 1 6 3 8 VLAN This pag...

Page 65: ...e lets you define several logical networks for each one you must set up the ID IP address and corresponding net mask Each VLAN definition may be individually enabled or disabled Also the definition ma...

Page 66: ...that will be available for the MobiLink IP equipment You can create new entries into the table enable edit save or delete them These Aliases can be seen in the NETWORK Status Web page of MobiLink IP...

Page 67: ...esponding required routes for the Aliases you defined are automatically added to the routing table of the MobiLink IP equipment After issuing a Commit the MobiLink IP box restarts and will be now acce...

Page 68: ...the two mobile interfaces of the equipment It has four sub sections one for displaying the current state another for configuring the mobile modules the third for locking the module to a certain mobil...

Page 69: ...see the current state below for Mobile 1 In case of equipments fitted with 3G modules an additional field show up indicating the technology of the mobile network 2G for GSM or 3G for UMTS HSPA Likewi...

Page 70: ...ration This is the technology GSM GPRS or UMTS HSDPA of the mobile network where the module is actually connected provided that the network allows this information MobiLink IP devices fitted with 2G G...

Page 71: ...t a smaller figure corresponds to a higher signal level For instance 91 dBm corresponds to a better signal quality than 101 dBm and 85 dBm is even better The last field is Audio AMR indicating the sta...

Page 72: ...Try again click Load later when finished with the voice call or the transmission of SMS messages 1 Likewise the value zero for the signal quality does not mean no signal at all it is simply the lowest...

Page 73: ...for 3G network and additional configuration field Network type will show up in this configuration page Click Edit of the Mobile Interface where you want to change the parameters Network Type option c...

Page 74: ...SMS messages it will not be available for interrogation so the request to set a different audio level will not be applied Note3 Do not change the audio level parameters unless necessary as this may af...

Page 75: ...ress More to continue The window which shows up includes all the settings for the respective module mobile2 in this example There was no room to display all the settings in the previous table which in...

Page 76: ...rk again Reset Timer for each module you can set up a time interval following which the respective module will be resetted Form the drop list that shows up you can select None default no resetting 5 m...

Page 77: ...can Edit the line for each of the two interfaces If you select Manual then you must also choose a certain operator from the drop list When Operator is left to the default any no locking is performed...

Page 78: ...s example has been edited for Romania and includes all mobile operators registered in our country For instance in the case of Australia the Operator List will look like this One Tel 505 08 Telstra Mne...

Page 79: ...sw1 2 21_revGen doc Page 79 of 188 6 4 4 AT Commands The last page of the Mobile section allows you to send AT commands directly to the GSM modules and see the respective results First select the GSM...

Page 80: ...1 or 1 for mobile 2 the command issued the response the result either OK or ERROR AT Commands AT commands are instructions used to control a modem Many of them initially used to control wired dial up...

Page 81: ...AT CMGW or delete AT CMGD SMS messages and obtain notifications of newly received SMS messages AT CNMI Control the presentation of result codes error messages of AT commands For example you can contro...

Page 82: ...ters for SMS to e mail and e mail to SMS conversion transmit or receive messages from the Web interface group sending of messages to several mobile numbers 6 5 1 Status Of course Status shows the curr...

Page 83: ...tor of the respective mobile networks Typically an SMSC address is an ordinary phone number in the international format ITU E 164 E 163 such as 20122000020 or 49 1715990000 There are also exceptions f...

Page 84: ...A Service Centre Address to read or set the address of the service center through which SMS messages will be sent out The command AT CSCA asks for the current SMSC address while the command in format...

Page 85: ...The default value is None meaning no erasing is performed You may choose one of the pre set time intervals for cleaning out the SMSs 5 minutes 10 minutes and so on up to 3 days which means that the m...

Page 86: ...Finally the rule no 3 says that SMSs with 074xxxxxxx destinations may be routed through any available mobile interface you can also force direct routing of messages no matter which is the real phone n...

Page 87: ...S to Email is disabled as shown in this example the received messages will be shown in the Receive page If you enable this feature the SMS messages as soon as they are received will be sent out as e m...

Page 88: ...91 instead of the standard one default value is 110 User name and associated password for the mail account SMS Outbox The User must be in form of user_mail customer com Authentication method used for...

Page 89: ...have entered in Subject SMS to E mail Settings for the reciprocal feature which converts received SMS into e mail messages Status you must Enable this feature in order to use it By default it is also...

Page 90: ...text password or with log in Check interval you set the value in seconds when MobiLink IP checks for new SMS to send out as e mail messages Mail agent log At the bottom of the mail configuring page th...

Page 91: ...pplications mail word processing etc For ASCII characters the maximum length is the standard one for SMS 160 characters The window Characters show you how may characters you have already typed 18 out...

Page 92: ...number of characters for a standard SMS is 160 characters in case of ASCII messages or 70 in case of non ASCII characters But you can send even longer text messages they will be broken into several c...

Page 93: ...new record and Edit to modify it The first field is the name of the recipient of the message This name is meaningful for the human operator only MobiLink IP has no use for it The next field is the des...

Page 94: ...or Delete All to delete all the SMS rows in a single operation Load CSV One of the links at the bottom of is Load CSV file You can use it to load a CSV comma separated value file previously created t...

Page 95: ...ng zero from the telephone number Since the comma is the separator the text of the message must NOT contain any comma If it encounters a comma the program will believe that this is the end of the text...

Page 96: ...l transmission the messages will be automatically deleted Group sending of a common message A variant of the group SMS operation is when you need to send a single message to several recipients phone n...

Page 97: ...e the link Edit All located at the bottom right to edit all the SMS Text fields at once In this window you can either enter the text by typing or paste it from a location where you copy the text of in...

Page 98: ...biLink IP SMS MobilinkIP_Usermanual sw1 2 21_revGen doc Page 98 of 188 Now you can start the process of transmitting the common message to all the destination numbers by simply pressing the Send butto...

Page 99: ...the Read SMS button to refresh the list of messages Date shows not only the date but also the time when the message has been sent up to seconds Also the time zone such as GMT 2 in case of Bucharest R...

Page 100: ...e onto your computer because it will be lost each time MobiLink IP is re booted The received messages are shown in this page only when the feature SMS to E mail is disabled If it is enabled the receiv...

Page 101: ...MobiLink IP SMS MobilinkIP_Usermanual sw1 2 21_revGen doc Page 101 of 188 Select Save File and go to the foldere where you want to store the saved text messages...

Page 102: ...pective folder and open up the saved SMS The Comma Separated Values format is understood by many applications for instance if you have Office applications installed it will be opened up as an Excel sp...

Page 103: ...starting with the one at the bottom it is normal that SMS 2 has already been successfully sent hence the message OK while SMS 1 is still waiting to be transmitted In the next example while sending out...

Page 104: ...t messages are kept with the status OK until the next transmission occurs Then they are automatically deleted to make room for the current messages which are waiting to be sent out via SMS service 6 6...

Page 105: ...figuration Web page as shown below However logical interfaces VLAN or aliases may also be used Or 6 6 2 Settings Here you can select which of the logical interfaces of the equipment shall be used for...

Page 106: ...ec G 711 on the first place either with A Law for Europe or u law for North America followed by G 729 G 711 provides good voice quality and works well with in band DTMF If the IP PBX or the SIP teleph...

Page 107: ...FO messages as digital telephone events Additionally when using the H323 protocol you can choose to transmit DTMF by using the H 245 Alphanumeric method Under the SIP protocol the INFO method would be...

Page 108: ...ding out DTMF for the H323 protocol In this case tones are sent out over the H 245 signaling channel rather than in band with voice traffic via RTP channel Rohde Schwarz Topex S A has implemented the...

Page 109: ...network towards VoIP The meaning of Tx and respectively Rx are reversed compared to the page Mobile Settings Echo In telephony echo cancellation means reducing or removing echo from a voice communica...

Page 110: ...o he may believe that the connection is broken VAD may be used advantageously together with echo cancellation by preventing echo from traveling across a network the capacity achieved through silence s...

Page 111: ...local port number must correspond to the port used for SIP by the correspondent remote equipment connected to MobiLink IP which is the SIP phone exchange Set up the DSCP Value for SIP SIP is the cont...

Page 112: ...MobiLinkIP equipment and performs all the tasks of call control management access routing logs and so on 6 7 1 Status Displays the current state of the ports of the embedded phone exchange as well as...

Page 113: ...through the MobiLinkIP The example above shows a single VoIP call coming from a Soft phone application running on computer with the IP address 192 168 144 151 in the local network and getting out of t...

Page 114: ...Mobile 1 and goes out as an SIP call through VoIP port 261 Note that in this case the IP destination addresses for signaling and RTP are different The SIP call goes to the extension 241 of the IP PBX...

Page 115: ...r By default the port used for SIP protocol is the standard 5060 but the user may change this value if the SIP PBX operates differently Likewise when you select H323 protocol instead of SIP the defaul...

Page 116: ...ill still be able to talk to the respective IP PBX the first line of the Access In list is set by default to the local network 192 168 0 0 with net mask 16 meaning that any user with an address type 1...

Page 117: ...ll will be accepted and a normal phone conversation may take place 6 7 4 Incoming Calls Settings for the incoming calls that means calls which come in through the mobile interfaces of the equipment He...

Page 118: ...l receive a DISA tone allowing him to dial the number of the local extension he wants to reach See below the routing of such a call coming in through interface Mobile1 and being connected to destinati...

Page 119: ...teway and he cannot be connected to the PBX or to the human operator He does not have information about the real number of the calling party he does not know from what local extension he was called To...

Page 120: ...h several rules for calls coming in from SIP and going out through the mobile interfaces Each rule may be individually enabled or disabled The program analyses the numbering the prefix of the phone nu...

Page 121: ...the prefix 079 it will go out through the interface Mobile1 and so on The prefix 0ff means zero followed by two digits no matter which ones one must use this format for compatibility all the prefixes...

Page 122: ...the first digit of the telephone number You can establish a time limit in seconds for the duration of outgoing calls such as 3200 seconds in this example Such limitation is especially useful when foll...

Page 123: ...MobiLink IP CALL CONTROL MobilinkIP_Usermanual sw1 2 21_revGen doc Page 123 of 188 The command help shows you all available commands Further on...

Page 124: ...p for each section of the log how much information will be stored Currently the sections available for the log are Voice over IP a single item SIP and respectively PBX Currently the sections available...

Page 125: ...rors will be logged while Devel is the maximum details setting everything is logged for the usage of developers These settings generate correspondingly more or less detailed log files from this minima...

Page 126: ...should choose the level of details most adequate for your operation None Error only Verbose or even more detailed Devel for developers only 6 7 8 Parameters Here you can enter several parameters for...

Page 127: ...sers There are two section the first one just shows the status 6 8 1 Status Shows the state of the registered users There are shown all attempts at registration to the IP PBX user and password and the...

Page 128: ...hile the NAT service remains open after a data packet is sent from MobiLink IP to the remote PBX to allow the PBX to call back the MobiLink IP equipment Both values are expressed in seconds 6 9 LOCAL...

Page 129: ...uential way each message This header field serves to order transactions within a dialog to provide a means to uniquely identify transactions and to differentiate between new requests and request retra...

Page 130: ...nding upon the actual settings of the PBX a single digit may be enough or you must specify several such as 50 6 9 3 Local Users Definition Register the SIP Users who will be able to use the MobiLink I...

Page 131: ...for use with any mobile modules Then select the Mode which describes how the incoming call from the respective mobile number will be treated by MobiLink IP There are two groups of three options direc...

Page 132: ...in the above table can benefit of the callback feature to prevent abuse Target when you select the mode Target you must also complete the field Target enter the number of the destination for the inco...

Page 133: ...a call back to the respective mobile number placing him in connection with the intended target This way the clients in the field will no longer be charged for the calls instead the billing will be for...

Page 134: ...ing for Call mode User instead of Trunk so the access will require authorization with user name and password Incoming calls only available for users who are registered to the IP PBX For those who are...

Page 135: ...s displays the current status of the MobiLinkIP equipment Syslog View shows the log file and allows you to save it Syslog Settings settings for the remote log Update you may perform firmware update or...

Page 136: ...ilinkIP_Usermanual sw1 2 21_revGen doc Page 136 of 188 6 10 1 Status Shows the status of the MobiLinkIP system In some firmware versions System Status and other special Admin functions may be protecte...

Page 137: ...system version such as system 1 0 8 MXX or system 1 0 9 MXX SAX in the examples above The application firmware and the operating system root or kernel may be updated separately according to the requi...

Page 138: ...l the applications running on the MobiLinkIP store their output messages status reports confirmation or error messages activity etc It is a plain text thus easy to interpret record of actions taken by...

Page 139: ...or of the user info debug messages info or warnings can be seen in the log The log is very helpful when troubleshooting It may be saved on a PC simply use Save As option of your browser for further ex...

Page 140: ...er that temporary stores the log default value is 256 Note the remote machine must have a collector program running to receive and store the syslog messages This collector is also known as a syslog se...

Page 141: ...in Upgrading Mode No Yes As you can see the default is No to prevent accidentally going to the mode of operation Upgrade If you do want to perform a software upgrade select YES from the drop list then...

Page 142: ...only the STATUS indicator is blinking showing network activity the LEDs for Mobile1 and Mobile 2 are turned off Since the phone exchange application during the updating process MobiLink IP is not avai...

Page 143: ...cal real interface since the VLANs and Aliases are created by the main application which now is not currently running In System you can both see the state of the equipment as shown in the image below...

Page 144: ...sw1 2 21_revGen doc Page 144 of 188 When in system mode you may also or look at the logs as shown next in the page Syslog View And most important you can also perform a firmware update Other options i...

Page 145: ...quired Firmware Update To perform a firmware update go to SYSTEM Update as shown in the next image The update firmware image must be on your desktop PC or notebook The image files are binaries that ha...

Page 146: ...are very important because you must always load a firmware image which corresponds to the type of your equipment when you have a M2J box you must update with an image type M2J and not M2O or M1J The...

Page 147: ...f 188 Enter the name of the update or click Browse to search for it on the system In the example below the image files are located in the folder Updates on the system partition of the hard disk drive...

Page 148: ...m as shown below Open it with a text editor such as Notepad copy the string of checksum from this file and paste it in the MobiLink IP web page in the field named Control Sum Finally click the Send bu...

Page 149: ...me but now you can see a red progress bar that shows the advance of the operation The update log shows every step of the update process install partition unlocking erasing writing Among other informat...

Page 150: ...MobiLink IP returns to the default 192 168 173 1 if you have changed it you will loose the address of your MobiLink equipment The StartApp button will start up the main application software running o...

Page 151: ...options of the Menu and the value shown for the free memory is smaller Warning Do not update the firmware unless there are problems with the MobiLinkIP gateway or the new firmware has a feature that y...

Page 152: ...he saved settings after having the equipment operating with the updated firmware 6 10 5 Password Allows the modification of passwords for the log in accounts in this case admin First of all use the Ac...

Page 153: ...will start operating with the factory default values for all parameters During the process Updating settings please wait and a red progress bar can be seen as shown below CAUTION Use this option care...

Page 154: ...then leave the RST button Now the equipment performs a reset with return to factory default settings This does NOT happed if you don t follow exactly the procedure described above for instance if you...

Page 155: ...P equipment Or The configuration file is called 1234567 cfg where the number 1234567 is the serial number of the motherboard of MobiLink IP such as 5109044 or 2709061 in the examples above Click the b...

Page 156: ...MobiLink IP CALL CONTROL MobilinkIP_Usermanual sw1 2 21_revGen doc Page 156 of 188 also one should change the default name number cfg into a name meaningful for the actual configuration...

Page 157: ...d back to perform changes Also one should perform a Save before using Update to load a new software image since the new firmware could erase some of the settings Such precautions are especially useful...

Page 158: ...ermanual sw1 2 21_revGen doc Page 158 of 188 Use Browse or Choose button to navigate to the location where the configuration file was saved Press Open choose the file then click the button Send below...

Page 159: ...Page 159 of 188 Now the MobiLink IP equipment starts to load the configuration file that you have selected First the message Updating settings please wait will start to blink and then a red progress b...

Page 160: ...set up the Local Time of the MobiLink IP equipment How to use The time date kept by the Real Time Clock of the equipment is the one synchronized form the distant NTP servers which provides UTC time un...

Page 161: ...ing those with half hour or quarter hour increment Note As you can see in the current example the time zone has been set to UTC 3 This is because in Romania like in most of Europe the Daylight saving...

Page 162: ...bottom of the Time Settings page Clicking the set Time link gets you to a sub page where you can manually set up any date and time you want no matter which is the real time provided by NTP servers or...

Page 163: ...u must use Commit to save the modifications the new time date will be lost upon restarting of the equipment 6 10 10 Cron Allows you to set up entries in the CronTab table Cron is an Unix utility Unix...

Page 164: ...to be run on it must also be numeric 0 7 Run This is the command that you want run at the respective moments Default is None which does nothing Currently you can use these commands CleanOut deletes t...

Page 165: ...ight on the 1st 10th 15th of each month Frequently reset a module If you need to reset a certain Mobile module every 5 minutes for instance the usage of Cron is quite difficult you should write in the...

Page 166: ...166 of 188 6 11 TOOLS These are instruments or tools for advanced debugging of the equipment they allow a specialist to capture and save detailed operation logs check for network hosts and so on 6 11...

Page 167: ...o begin capture The screen now shows the message capture Running and the name of the button changes to Stop Click it to stop the capture Now the message says Capture stopped You can pres Init to go to...

Page 168: ...later to send the downloaded capture to the specialists support team or to look at it yourself You can change the default directory or make a special folder to store the captures if you use frequently...

Page 169: ...apture operation It is a text file whose name indicates the day when it was created such as 30 06 10 in this example 14 40 55 847439 65535 59 SendDebugToH323 M_H323DEBUG 14 40 55 848797 65535 59 SendD...

Page 170: ...obiLink IP The advanced settings for the Capture tool include activation of the Capture feature enable capturing upon starting up of MobiLink IP at boot and duration of this reboot capture establish d...

Page 171: ...e capture will begin immediately as MobiLink IP starts operating and will continue for the duration established in the field Capture Timeout MobiLink IP will run the Capture utility immediately as it...

Page 172: ...y the first three checkboxes are marked by default The modifications that you perform in Settings will be found again in capture in Capture only if you have pressed the button Commit while you were in...

Page 173: ...stopped the Capture by clicking the Stop button you have three options as shown in the image to the left press Init to erase the Capture archive that was created and to go back to the initial configur...

Page 174: ...1 3 Download Capture When you press the link Download Capture the window Opening capture tar shows up indicating that your computer tries to open the capture archive which is located on the MobiLinkIP...

Page 175: ...ge the default name of the capture file into one that is more meaningful to you In the example below the capture files the latest one being renamed as cap zetix2 are stored in the directory named CAPT...

Page 176: ...utility which knows to unpack tar archives Depending upon the configuration you have selected the Capture archive may contain a single text log or several files The text file is the Capture log itsel...

Page 177: ...MobiLink IP CALL CONTROL MobilinkIP_Usermanual sw1 2 21_revGen doc Page 177 of 188 You can open it with dump pcap Ethereal or WireShark program as shown in the following examples Or like this...

Page 178: ...pt requests It used diagnostically to ensure that a host computer the user is trying to reach is actually operating to test connectivity and determine response time Enter the address and click the Sen...

Page 179: ...Usermanual sw1 2 21_revGen doc Page 179 of 188 When the host is unavailable you will receive no specific error message but you will see that no packets get through the answer is something like this 0...

Page 180: ...800 900MHz 32dBm Power Class 4 GSM GPRS EDGE 1800MHz 29 dBm Power Class 1 UMTS HSDPA 2100MHz 23dBm Power Class 3 8PSK mode Class E2 only for devices fitted with 3G modules Receiver static sensitivity...

Page 181: ...ctric motors or heaters In addition it should not be placed near copiers PC monitors TV sets or other audio video appliances In order to ensure adequate working temperature the MobiLinkIP interface mu...

Page 182: ...ion Use only the provided power supply adapter and interconnecting cabling provided with the equipment Substitution of provided power supply and cabling may compromise electrical safety or CE Mark Cer...

Page 183: ...s to the destination where a special facility can read and display them or make them available for call center programming For example a company may have a different toll free number for each product...

Page 184: ...sers have access to Here the firewall is software a set of configurable related programs residing on the MobiLink IP gateway that protect the resources of the local internal network Gateway A network...

Page 185: ...ork hardware such as an Ethernet cards modems or wireless adaptors on a LAN or WAN The first part of the address is unique to the company that produced the device and beyond that it is a sequence of d...

Page 186: ...of communication in which a computer user a client requests and is provided a service such as sending a Web page by another computer a server in the network TCP IP is a two layer program The higher l...

Page 187: ...that generates the message UDP is used often in applications such as videoconferencing or games where optimal performance is preferred over guaranteed message delivery VoIP Acronym for Voice over IP I...

Page 188: ...d stored in a retrieval system or transmitted in any form or by any means electronic mechanical recording or otherwise without the prior written permission of the company ROHDE SCHWARZ TOPEX S A S A I...