EN
83
14
Examples of applications in parking access mode.
The
CTRL
controller manages the system in parking access mode.
The function is enabled through the parameter
and ONLY the
AP
and/or
PED
command inputs at the terminal board must be used.
N.B.:
the input
FT
cannot be disabled in the following operating situations. If the contact (NC) is opened during a closing manoeuvre, the barrier
reopens and remains open until the contact is closed again.
• Bi-directional mode with immediate closure
(
)
When entering and leaving the parking area, the barrier is opened with an
AP
open command (terminal block or radio command).
Once the vehicle has crossed the barrier and released contact
FT
(NC) (e.g. from magnetic loop), the barrier closes immediately.
When parameter
=
, the barrier open and remains open until the vehicle has completed the passage. If the vehicle moves back, the
barrier remains open.
If parameter
has a value different from
, the barrier re-closes after an automatic re-closure set time.
NOTE
: it is possible to add further 5 s delay before closing, setting
$
.
FT
AP
FT
AP
FT
FT
• Directional mode 1
(
)
When entering the parking area, the barrier is opened with an
AP
open command (terminal block).
Once the vehicle has crossed the barrier and released contacts
FT
(NC) and
PED
(NO), the barrier closes.
When leaving the parking area, the barrier is opened by a
PED
command received from the magnetic loop.
Once the vehicle has crossed the barrier and released contact
FT
(NC), the barrier closes.
When parameter
=
, the barrier open and remains open until the vehicle has completed the passage. If the vehicle moves back, the
barrier remains open.
If parameter
has a value different from
, the barrier re-closes after an automatic re-closure set time.
NOTE
: it is possible to add further 5 s delay before closing, setting
$
.
FT
PED
FT
PED
AP
FT
PED
FT
PED
•
Directional mode 2
(
)
When entering, the barrier is opened with an
AP
open command (terminal block), and closes after the automatic closing time set with pa-
rameter
.
NOTE
: in order to have the automatic closing set parameter
different to
.
When leaving the parking area, the barrier is opened by a
PED
(NO) command received from the magnetic loop.
Once the vehicle has crossed the barrier and released contact
FT
(NC), the barrier closes.
NOTE
: it is possible to add further 5 s delay before closing, setting
$
.
FT
PED
Tempo di chiusura
automaca
Automac closing
me
FT
PED
AP
FT
PED
FT
PED