EN
79
Photocell (FT) mode with barrier closed
N.B.:
this parameter is not visible if the value of parameter
=
,
or
or if
$
=
,
or
If the photocell is obstructed, the barrier cannot open.
The barrier opens when an open command is received, even if the photocell is obstructed.
The photocell sends the barrier open command when obstructed.
Enable close command 6 s after activation of photocell (FT)
N.B.:
This parameter is not visible if
$
or
$
is set, and if value of parameter
=
,
or
.
Disabled.
Enabled. When the photocell barrier FT is crossed, a close command is sent 6 seconds later.
Motor stop distance setting.
The motor brake function is activated each time a stop is requested by a user command or by activation of
the photocells.
Set a value that will prevent collision with objects or persons due to the inertia of the boom.
01= rapid braking/smaller stopping distance ...
10= gentle braking (soft-stop)/greater stopping distance (
NOTE
: recommended setting for bars longer than 4 m).
N.B.:
Available values may be limited by the setting for parameter
$
.
Installation position of barrier relative to gateway (seen from interior side)
For installations with two opposed barriers, this setting must be made for the MASTER barrier. The SLAVE
barrier recognises its position automatically.
N.B.:
every time the installation position is changed by altering parameter
, the display shows a position
data request message
GDWD
. Press the
PROG
key until
$33
appears on the display, then repeat the
acquisition procedure (see fig. 21 and chapter 11.2).
Barrier installed on the left, viewed from the inspection cover side. With passage opening on the right.
Barrier installed on the right, viewed from the inspection cover side. With passage opening on the left.
Sensing edge COS configuration
Sensing edge NOT INSTALLED.
NC contact (normally closed). The barrier reverses only when closing.
Contact with 8k2 resistor. The barrier reverses only when closing.
Radio channel 1 configuration (PR1)
Radio channel 2 configuration (PR2)
STEP MODE.
PARTIAL OPENING.
OPENING.
CLOSING.
STOP.
STEP MODE with confirmation for safety
(1)
.
PARTIAL OPENING with confirmation for safety
(1)
.
OPEN with confirmation for safety
(1)
.
CLOSE with confirmation for safety
(1)
.
(1)
To prevent barrier manoeuvres caused by accidentally pressing a remote control button, confirmation is required to enable the command.
Example: parameters
e
set:
• Pressing the CHA button on the remote control selects the step mode function, which must be confirmed within 2 seconds by pressing CHB
on the remote control. Press CHB to activate partial opening.
Flashing light / upper cover lights frequency configuration
The frequency is set electronically from the flashing light unit.
Slow flash. The light flashes at a lower frequency when the boom is near the mechanical stops.
Light flashes slowly when barrier opens, rapidly when barrier closes. The light flashes at a lower frequency
when the boom is near the mechanical stops.
Summary of Contents for CTRL
Page 2: ...2 ...
Page 19: ...19 AGILIK KB MESSA A TERRA GROUNDING SCHEME 16 ...
Page 20: ...20 17 MESSA A TERRA GROUNDING SCHEME BIONIK4 BIONIK4HP BIONIK6 BIONIK8 ...
Page 290: ...290 ...
Page 291: ...291 ...