Enable close command after activation of photocell (FT)
N.B.
: this parameter is not visible if
.
Disabled.
Enabled. The barrier stops if the photocell is activated during closing manoeuvre. The barrier resumes clos-
ing when the photocell is cleared.
Selection of the battery operation management
Setting a value different than
a battery voltage level check is activated. The desired operation type can
be selected via parameter
and an error alert can be activated through the SC output via parameter
.
The control unit always accepts commands until the battery is completely exhausted.
The command becomes active when the battery voltage drops to the minimum threshold (22Vdc for battery
2x12Vdc)
The command becomes active when the battery voltage drops to the medium threshold (23Vdc for battery 2x12Vdc)
The command becomes active when the battery voltage drops to the maximum threshold (24Vdc for battery
2x12Vdc)
Selecting the battery operation limitations.
N.B.:
the parameter is visible only if par.
is different than
There is no limitation for the commands when the battery voltage drops under the selected threshold. An error alert
may be activated via the SC output (if parameters
and
are adequately set).
When the battery voltage drops under the threshold selected with par.
, the control unit accepts only opening
commands and does not perform closing.
When the battery voltage drops under the threshold selected with par.
, after a 5 s pre-flashing, the control unit
automatically opens the barrier's boom and accepts only a closing command.
It accepts only closing commands even if the ORO input is active and if the parameter is
.
Selection of the battery type and consumption reduction
NOTE
: An INCORRECT setting of this parameter, when there is no mains voltage, blocks the functions and the display
shows the message
EW/2
(if set to
or
and the battery is 2x12Vdc) or an error alert
E RG
.
Battery 24Vdc (2x12V). Acceleration/deceleration/speed reduction enabled, to increase the battery life.
Battery 36Vdc (3x12V). Acceleration/deceleration/speed reduction enabled, to increase the battery life. - DO NOT
SELECT. FUTURE USE -
Battery 36Vdc (3x12V). No performance reduction, maximum battery consumption. - DO NOT SELECT. FUTURE
USE -
Restoring factory default values
NOTE
This procedure is only possible is NO data protection password is set.
N.B.:
This parameter is not visible for the SLAVE barrier.
P1
P2
x4 s
+
-
Warning!
Restoring default settings cancels all settings made previously except for parameters
$
,
$
and
: after restore, check that all parameters are suitable for the installation.
The default factory settings may also be restored using the
+
(PLUS) and/or
-
(MINUS) buttons as follows:
• Turn off the power.
• Press and hold the
+
(PLUS) and
-
(MINUS) buttons until the unit switches on.
• The message
U(V
flashes on the display after 4 s.
• The default factory settings have now been restored.