EN
63
6
Description of connections
To access the control unit. remove the barrier head.
Figure 1-2-3
shows connection diagrams.
6.1
Typical installation
2
2
3
3
4
1
5
Recommended cable
1
Power supply
H07RN-F 3x1,5 mm2 double insulated cable
2
Photocell - Receiver F4ES/F4S
Cable 4x0,5 mm
2
(max 20 m)
3
Photocell - Transmitter F4ES/F4S
Cable 2x0,5 mm
2
(max 20 m)
4
Key selector R85/60
Cable 3x0,5 mm
2
(max 20 m)
Keypad H85/TTD - H85/TDS (connecting to control panel to decoder
board H85/DEC - H85/DEC2)
Cable 3x0,5 mm
2
(max 20 m)
5
Barrier open indicator
Power supply 24V DC 3W max
Cable 2x0,5 mm
2
(max 20 m)
SUGGESTIONS:
with existing installations, we recommend checking the cross section of the cables and that the
cables themselves are in good condition.