Diagnostics
8-3
Fault Codes
Table 8.A provides a complete cross-reference of the available fault
codes and corresponding fault descriptions.
Table 8.A Fault Code Cross-reference
➀
See Table 8.B for definition.
Fault and Alarm Auxiliary
Indication for Fault or Alarm
Auxiliary contacts can be programmed for Fault or Alarm, N.O. or
N.C. indication. Parameter setup can be found in the Parameter/Motor
Protection group when modifying parameters in the Program Mode.
Fault
Code
Fault
Code
Line Loss A
1
Stall
25
Line Loss B
2
Phase Reversal
26
Line Loss C
3
Coms Loss P2
27
Shorted SCR A
4
Coms Loss P3
28
Shorted SCR B
5
Coms Loss P5
29
Shorted SCR C
6
Network P2
30
Open Gate A
7
Network P3
31
Open Gate B
8
Network P5
32
Open Gate C
9
Ground Fault
33
PTC Pwr Pole
10
Excess Starts
34
SCR Overtemp
11
Power Loss A
35
Motor PTC
12
Power Loss B
36
Open Bypass A
13
Power Loss C
37
Open Bypass B
14
Hall ID
38
Open Bypass C
15
NVS Error
39
No Load A
16
No Load
40
No Load B
17
Line Loss A
41
➀
No Load C
18
Line Loss B
42
➀
Line Unbalance
19
Line Loss C
43
➀
Overvoltage
20
V24 Loss
45
Undervoltage
21
V Control Loss
46
Overload
22
Input 1
48
Underload
23
Input 2
49
Jam
24
System Faults
128…209
Summary of Contents for SMC-Flex
Page 1: ...USER MANUAL FOR SERIES B SMC Flex BULLETIN 150...
Page 4: ...Notes...
Page 30: ...1 22 Product Overview Notes...
Page 126: ...9 8 Troubleshooting...
Page 148: ...B 14 Parameter Information Notes...
Page 150: ...C 2 Renewal Parts Notes...
Page 156: ...E 2 Accessories Notes...