Specifications and Site Requirements
Electrical Specifications
64
MagneMotion
Rockwell Automation Publication MMI-UM013B-EN-P - April 2020
Electrical Specifications
NC-S Node Controller
24–48V DC ±10%, 10 W max based on configuration and operating mode. See
for the mechanical drawing.
AC Power Option
The optional remote power supply for the NC-S node controller requires 90–264V AC @ 47–
63 Hz, single-phase (phase-to-phase or phase-to-neutral), 0.7 A at 100V AC (25 W max).
Inrush current 45 A/240V AC max The actual power being drawn depends on the operations
being performed. However, all power wiring must be designed to carry the full load. See the
data sheet provided by the power supply manufacturer for mechanical information.
AC Power Cable
The optional remote power supply for the NC-S node controller is supplied with a power
cable. Contact MagneMotion for replacement cables. The AC power cable plugs directly into
the power supply.
DC Power Option
DC power from a user-supplied power supply requires 24–48V DC, 10 W.
The actual power being drawn depends on the operations being performed. Make sure that all
power wiring can carry the full load and has a limited power source or the power source is
fused to the maximum rating of the wiring.
CAUTION
High-Voltage Hazard
90–264V AC, 25 W
AC power must be disconnected before servicing.
NOTICE
Any user-supplied power supply must be NRTL/ATL approved.
NOTICE
The NC-S node controller does not support Power over Ethernet. Never con-
nect these node controllers to a powered network as damage to internal com-
ponents can result.