Programming and Parameters
3-13
MO
T
O
R CONTR
O
L
To
rq
At
tri
b
ut
es
066
[Autotune Torque]
Specifies motor torque applied to the
motor during the flux current and inertia
tests performed during an autotune.
Default:
Min/Max:
Units:
50.0%
0.0/150.0%
0.1%
067
[Inertia Autotune]
Provides an automatic method of setting
[Total Inertia]. This test is automatically
run during Start-Up motor tests.
Important:
If using rotate tune for
“Sensrls Vect” mode, the motor should be
uncoupled from the load or results may
not be valid. With “FVC Vector,” either a
coupled or uncoupled load will produce
valid result.
“Ready” = Parameter returns to this
setting following a completed inertia tune.
“Inertia Tune” = A temporary command
that initiates an inertia test of the motor/
load combination. The motor will ramp up
and down, while the drive measures the
amount of inertia.
Default:
Options:
0
0
1
“Ready”
“Ready”
“Inertia Tune”
427
431
[Torque Ref A Sel]
[Torque Ref B Sel]
Selects the source of the external torque
reference to the drive. How this reference
is used is dependent upon [Speed/
Torque Mod].
(1)
See
Appendix B
for DPI port locations.
Default:
Options:
1
24
0
1
2
3-17
18-22
23
24
25-28
29
“Torque Stpt1”
“Disabled”
“Torque Stpt1”
“Analog In 1”
“Analog In 2”
“Reserved”
“DPI Port 1-5”
(1)
“Reserved”
“Disabled”
“Scale Block1-4”
“Torque Stpt2”
428
432
[Torque Ref A Hi]
[Torque Ref B Hi]
Scales the upper value of the [Torque Ref
A Sel] selection when the source is an
analog input.
Default:
Min/Max:
Units:
100.0%
100.0%
–/+800.0%
0.1%
429
433
[Torque Ref A Lo]
[Torque Ref B Lo]
Scales the lower value of the [Torque Ref
A Sel] selection when the source is an
analog input.
Default:
Min/Max:
Units:
0.0%
0.0%
–/+800.0%
0.1%
430
[Torq Ref A Div]
Defines the value of the divisor for the
[Torque Ref A Sel] selection.
Default:
Min/Max:
Units:
1.0
0.1/3276.7
0.1
434
[Torque Ref B Mult]
Defines the value of the multiplier for the
[Torque Ref B Sel] selection.
Default:
Min/Max:
Units:
1.0
–/+32767.0
0.1
Fi
le
Gr
ou
p
No.
Parameter Name & Description
See
page 3-2
for symbol descriptions
Values
Relate
d
FV
FV
FV
FV
FV
FV
FV
Summary of Contents for Allen-Bradley PowerFlex 700 B Series
Page 10: ...P 6 Overview Notes ...
Page 36: ...1 26 Installation Wiring Notes ...
Page 118: ...3 78 Programming and Parameters Notes ...
Page 162: ...A 28 Supplemental Drive Information Notes ...
Page 227: ......