3-8
Programming and Parameters
MONIT
O
R
Metering
014
[Elapsed kWh]
Accumulated output energy of the drive.
Default:
Min/Max:
Units:
Read Only
0.0/429496729.5 kWh
0.1 kWh
016
017
[Analog In1 Value]
[Analog In2 Value]
Value of the signal at the analog inputs.
Default:
Min/Max:
Units:
Read Only
0.000/20.000 mA
–/+10.000V
0.001 mA
0.001 Volt
018
[PTC HW Value]
Value present at the drive's PTC input
terminals.
Default:
Min/Max:
Units:
Read Only
–/+5.00 Volts
0.01 Volts
021
[Spd Fdbk No Filt]
Displays the unfiltered value of the actual
motor speed, whether measured by
encoder feedback or estimated.
Default:
Min/Max:
Units:
Read Only
–/+400.0 Hz
–/+24000.0 RPM
0.1 Hz
0.1 RPM
022
[Ramped Speed]
Value of commanded speed after Accel/
Decel, and S-Curve are applied.
Default:
Min/Max:
Units:
Read Only
–/+400.0 Hz
–/+24000.0 RPM
0.1 Hz
0.1 RPM
023
[Speed Reference]
Summed value of ramped speed,
process PI and droop. When FVC Vector
mode is selected, droop will not be
added.
Default:
Min/Max:
Units:
Read Only
–/+400.0 Hz
–/+24000.0 RPM
0.1 Hz
0.1 RPM
024
[Commanded Torque]
Final torque reference value after limits
and filtering are applied. Percent of motor
rated torque.
Default:
Min/Max:
Units:
Read Only
–/+800.0%
0.1%
025
[Speed Feedback]
Displays the lightly filtered value of the
actual motor speed, whether measured
by encoder feedback, or estimated.
Default:
Min/Max:
Units:
Read Only
–/+400.0 Hz
–/+24000.0 RPM
0.1 Hz
0.1 RPM
Drive Data
026
[Rated kW]
Drive power rating.
Default:
Min/Max:
Units:
Read Only
0.00/3000.00 kW
0.01 kW
027
[Rated Volts]
The drive input voltage class (208, 240,
400 etc.).
Default:
Min/Max:
Units:
Read Only
0.0/65535.0 VAC
0.1 VAC
028
[Rated Amps]
The drive rated output current.
Default:
Min/Max:
Units:
Read Only
0.0/65535.0 Amps
0.1 Amps
Fi
le
Gr
ou
p
No.
Parameter Name & Description
See
page 3-2
for symbol descriptions
Values
Relate
d
FV
Summary of Contents for Allen-Bradley PowerFlex 700 B Series
Page 10: ...P 6 Overview Notes ...
Page 36: ...1 26 Installation Wiring Notes ...
Page 118: ...3 78 Programming and Parameters Notes ...
Page 162: ...A 28 Supplemental Drive Information Notes ...
Page 227: ......