3-26
Programming and Parameters
Dynamic Control File
SPEE
D COMMAN
D
Speed
Re
gul
ato
r
450
[Total Inertia]
Represents the time in seconds, for a
motor coupled to a load to accelerate
from zero to base speed, at rated motor
torque. The drive calculates Total Inertia
during the autotune inertia procedure.
Adjusting this parameter will cause the
drive to calculate and change [Ki Speed
Loop] and [Kp Speed Loop] gains.
Default:
Min/Max:
Units:
0.10 Secs
0.01/600.00
0.01 Secs
451
[Speed Loop Meter]
Value of the speed regulator output.
(1)
“%” if [Motor Cntl Sel] = “FVC Vector.”
Default:
Min/Max:
Units:
Read Only
–/+800.0%
(1)
–/+800.0 Hz
–/+800.0 RPM
0.1%/Hz/RPM
Fi
le
Gr
ou
p
No.
Parameter Name & Description
See
page 3-2
for symbol descriptions
Values
Relate
d
FV
FV
Fi
le
Gr
ou
p
No.
Parameter Name & Description
See
for symbol descriptions
Values
Re
la
te
d
D
YNAMIC CONTR
O
L
Ramp Rates
140
141
[Accel Time 1]
[Accel Time 2]
Sets the rate of accel for all speed
increases.
Default:
Min/Max:
Units:
10.0 Secs
10.0 Secs
0.0/3600.0 Secs
0.1 Secs
142
143
[Decel Time 1]
[Decel Time 2]
Sets the rate of decel for all speed
decreases.
Default:
Min/Max:
Units:
10.0 Secs
10.0 Secs
0.0/3600.0 Secs
0.1 Secs
146
[S Curve %]
Sets the percentage of accel or decel
time that is applied to the ramp as S
Curve. Time is added, 1/2 at the
beginning and 1/2 at the end of the ramp.
Default:
Min/Max:
Units:
0%
0/100%
1%
thru
L
oad Li
mit
s
147
[Current Lmt Sel]
Selects the source for the adjustment of
current limit (i.e. parameter, analog input,
etc.).
Default:
Options:
0
0
1
2
“Cur Lim Val”
“Cur Lim Val”
“Analog In 1”
“Analog In 2”
Max Speed
Accel Time
Accel Rate
=
Max Speed
Decel Time
Decel Rate
=