18
Rockwell Automation Publication 520-UM001K-EN-E - August 2021
Chapter 1 Installation/Wiring
Derating Guidelines for High Altitude
The drive can be used without derating at a maximum altitude of
1000 m (3300 ft). If the drive is used above 1000 m (3300 ft):
•
Derate the maximum ambient temperature by 5 °C (9 °F for every
additional 1000 m (3300 ft), subject to limits listed in the
Or
•
Derate the output current by 10% for every additional 1000 m (3300 ft),
up to 3000 m (9900 ft), subject to limits listed in the
High Altitude
Debris Protection
Take precautions to prevent debris from falling through the vents of the drive
housing during installation.
Storage
•
Store within an ambient temperature range of -40...85 °C
(1)
.
•
Store within a relative humidity range of 0...95%, noncondensing.
•
Do not expose to a corrosive atmosphere.
(1) The maximum ambient temperature for storing a Frame E drive is 70 °C.
Altitude Limit (Based on Voltage)
Drive Rating
Center Ground (Wye Neutral)
Corner Ground, Impedance Ground,
or Ungrounded
100...120V 1-Phase
6000 m
6000 m
200...240V 1-Phase
2000 m
2000 m
200...240V 3-Phase
6000 m
2000 m
380...480V 3-Phase
4000 m
2000 m
525...600V 3-Phase
2000 m
2000 m
Altitude (m)
Percentage of Rated Current (%)
40
90
100
110
120
80
70
60
50
0
4000
3000
2000
1000
Altitude (m)
Ambient Temperature (°C)
20
50
60
40
30
0
4000
3000
2000
1000
Summary of Contents for Allen-Bradley PowerFlex 520 Series
Page 8: ...8 Rockwell Automation Publication 520 UM001K EN E August 2021 Table of Contents Notes ...
Page 68: ...68 Rockwell Automation Publication 520 UM001K EN E August 2021 Chapter 2 Start Up Notes ...
Page 236: ...236 Rockwell Automation Publication 520 UM001K EN E August 2021 Appendix F PID Set Up Notes ...
Page 270: ...270 Rockwell Automation Publication 520 UM001K EN E August 2021 Index Notes ...