184
Rockwell Automation Publication 35-UM001A-EN-P - May 2022
Chapter 7 Configure the Armor PowerFlex Drive
DeviceName.O.DirectionCmd_0
DeviceName.O.DirectionCmd_1
0,0 or 1,1 = No direction commanded, current direction is
maintained
1,0 = Forward direction commanded
0,1 = Reverse direction commanded
DeviceName.O.ClearFault
A 0 to 1 transition will acknowledge or clear all active
faults
DeviceName.O.AccelRefSelect_0
DeviceName.O.AccelRefSelect_1
DeviceName.O.AccelRefSelect_2
0,0,0 = Use default acceleration reference (usually
Acceleration Preset 1)
For configuration, see
0,0,1 = Use Acceleration Preset 1
0,1,0 = Use Acceleration Preset 2
0,1,1 = Use Acceleration Preset 3
1,0,0 = Use Acceleration Preset 4
DeviceName.O.VelocityRefSelect_0
DeviceName.O.VelocityRefSelect_1
DeviceName.O.VelocityRefSelect_2
0,0,0 = Use velocity reference in output tag
(CommandedVelocity)
For configuration, see
1,0,0 = Use Velocity Preset 1
0,1,0 = Use Velocity Preset 2
1,1,0 = Use Velocity Preset 3
0,0,1 = Use Velocity Preset 4
DeviceName.O.IO_0
Controls the state of the self-configuring I/O point 0
0 = output off / input mode, 1 = output on
If using this I/O point as an input, this should remain 0
DeviceName.O.IO_1
Controls the state of the self-configuring I/O point 1
0 = output off / input mode, 1 = output on
If using this I/O point as an input, this should remain 0
DeviceName.O.EMBrakeRelease
1 = Manually release (energize) the EM brake
(This tag member is ignored on units without EM brake
control circuitry)
DeviceName.O.CommandFrequency
Dynamic velocity reference value, used if
DeviceName:O.VelocityRefSelect = 0,0,0
Table 75 - Safety Input Tags
Safety Input Tags
Function
DeviceName.SI.ConnectionStatus
Reserved for future use; always 0.
DeviceName.SI.RunMode
Reserved for future use; always 0.
DeviceName.SI.ConnectionFaulted
Reserved for future use; always 0.
DeviceName.SI.FeedbackPosition
Indicates the actual position of the feedback device.
DeviceName.SI.FeedbackVelocity
Indicates the Feedback velocity, the actual velocity of the
feedback device.
DeviceName.SI.StopStatus
A collection of the following bits.
DeviceName.SI.STOActive
Safe Torque Off (STO) function status
0 = Permit Torque
1 = Disable Torque
DeviceName.SI.SBCActive
Safe Brake Control (SBC) function status
0 = Release Brake
1 = Engage Brake
DeviceName.SI.SS1Active
Safe Stop 1 (SS1) function status:
0 = Not Active
1 = Active
DeviceName.SI.SafetyFault
1 = Safe Stop Fault present
DeviceName.SI.RestartRequired
1 = Fault Reset or Stop Restart is required
DeviceName.SI.SafeStatus
A collection of the following bits.
DeviceName.SI.TorqueDisabled
0 = Torque Permitted
1 = Torque Disabled
DeviceName.SI.BrakeEngaged
Indicates the status of SBC function:
0 = Brake Released
1 = Brake Engaged
DeviceName.SI.MotionStatus
Reserved for future use; always 0.
Table 74 - Standard Output Tags
Output Tag
Function