Rockwell Automation Publication 35-UM001A-EN-P - May 2022
153
Chapter 7 Configure the Armor PowerFlex Drive
Configure Motor Nameplate
From the Motor Control page, enter Motor Nameplate values based on your
system configuration.
Enter motor nameplate data for Voltage, Frequency, and Full Load Current.
IMPORTANT
The motor nameplate values entered must match the actual
characteristics of the connected motor. Do not use the default
values if they do not match. If these values are incorrect, poor
motor control performance, faults, and other undesired behavior
can result.
Size: 1 Hp (35S-6D1-*, 35E-6D1-*)
Motor Nameplate
Minimum
Maximum
Default
Voltage
20V AC
460V AC
460V AC
Frequency
0 Hz
500 Hz
60 Hz
Rated Speed
0 RPM
24,000 RPM
1750 RPM
Rated Power
0 kW
0.75 kW
0.75 kW
Pole Count
2
N/A
4
Full Load Amps rms
0.0652 A
2.3 A
2.3 A
Size: 2 Hp (35S-6D2-*, 35E-6D2-*)
Motor Nameplate
Minimum
Maximum
Default
Voltage
20V AC
460V AC
460V AC
Frequency
0 Hz
500 Hz
60 Hz
Rated Speed
0 RPM
24,000 RPM
1750 RPM
Rated Power
0 kW
1.5 kW
1.5 kW
Pole Count
2
N/A
4
Full Load Amps rms
0.0652 A
4.0 A
4.2 A
Size: 3 Hp (35S-6D3-*, 35E-6D3-*)
Motor Nameplate
Minimum
Maximum
Default
Voltage
20V AC
460V AC
460V AC
Frequency
0 Hz
500 Hz
60 Hz
Rated Speed
0 RPM
24,000 RPM
1750 RPM
Rated Power
0 kW
2.2 kW
2.2 kW
Pole Count
2
N/A
4
Full Load Amps rms
0.0652 A
6.0 A
6.0 A