9
1.1 Technical specifications
Parameter
Model
G 450 TC
G 450 TC +Plus 250
Minimum - Maximum draught
(Pa)
11-13
Fuel consumption
(kg/h)
4,49
4,36
Smoke mass flow rate
(g/s)
12,3
13,2
Efficiency
(%)
82
85,4
Nominal output
(kW)
16,3
16,5
Power range
(kW)
11 – 19,5
11 – 19,5
Average CO concentration at 13% of O
2
:
(%)
0,085
0,076
Average NO
x
concentration at 13% of O
2
:
(mg/Nm
3
)
101
101
Average OGC concentration at 13% of O
2
:
(mg/Nm
3
)
59
52
Particle concentration at 13% of O
2
:
(mg/Nm
3
)
17,6
17,1
Medium draft:
(test Pa)
11,1
10,9
Net weight:
(kg)
319
346
Maximum authorized load:
(kg)
5
5
Reload height:
(mm)
200
200
Logs length
(mm)
550
550
Minimum flue height:
(mm)
4000
Ø Flue duct:
(mm)
250
250
Ø Air inlet:
(mm)
120
Ø Hot air outlet:
(mm)
120
Inner fireplace room safety distances:
(back)
(mm)
20
Inner fireplace room safety distances:
(sides)
(mm)
20
Outer fireplace safety distances
(back)
(mm)
300
Outer fireplace safety distances
(sides)
(mm)
900
Outer fireplace safety distances
(frontal)
(mm)
1000
Fireplace room ventilation (entry - exit) (cm
2
)
450
Minimum safety distance to hot air outlets
(mm)
250
Average temperature of smoke
(ºC)
259,2
196,6
Type of combustion
INTERMITENT
Flue liner
NOT SHARED
Fuel
NATURAL WOOD
Humidity fuel logs
12-20 % - two years under cover
Certification year
2020
2020
Certificate number
1880-CPR-035-20
1880-CPR-037-20
1.2 Breakdown of delivery components
(
Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1.
Fireplace’s body.
2.
Ceramic rope joint.
3.
External air inlet cover and external air inlet tconnector
ᴓ
120 mm
4.
7x
ᴓ
120 mm aluminium ring
5.
4x Levelling and adjustable foots.
6.
Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.
7.
Sliding door opening adjustment pieces.
8.
Bag with 24x screws (G 450 TC, G 450 TC +Plus 250).
9.
Bag with metallic clamp, 2x screws to fix air inlet connector/cover, 2x washer to fix air inlet connector/cover and 4x nuts to
install leveling and adjustable feets.
10.
Cleaning cloth
11.
Heat-resistant glove.
12.
Tool for handling registers and opening door.
13.
Heat-resistant spray paint for touch-ups.
14.
Optional: +Plus 250 (G 450 TC +Plus 250)
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I.
ATTENTION:
The measurements admit a tolerance of 0.3%.
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH
UPON INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground.
Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2.2 Flue liner.
It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside in observation
of the smoke pipe diameter.
The good condition and suitability of this smoke pipe must be certified by a professional and
must also observe the relevant national regulations
. This Flue liner should not be shared with other devices (see Table 1.1
1. SPECIFICATIONS
2. REQUIREMENTS PRIOR TO INSTALLATION
Summary of Contents for G 450 TC
Page 33: ......
Page 34: ...1 ANEXO ANNEX ANNEXE ANESSO I G 450 TC...
Page 35: ...2 I G 450 TC Plus 250...
Page 36: ...3 II 1 11 13 10 4 2 5 3 6 7 8 9 12...
Page 37: ...4 III 1 2...
Page 38: ...5 III 1 2 3 4 5 6...
Page 39: ...6 III 7 8 9 9 1 Plus 250 9 2 Plus 250 10...
Page 40: ...7 III A 1 A 2 A 3 B 1 B 1 B 2...
Page 41: ...8 III B 3 B 4...
Page 42: ...9 IV C 1 A C 1 B C 2 C 3 C 4 C 5...
Page 43: ...10 IV C 6 C 7 C 8 C 9 C 10 C 11...
Page 44: ...11 IV C 12 C 13 C 14 C 15 C 16 C 17...
Page 45: ...12 IV C 18 C 19...
Page 47: ...14 NOTES...
Page 48: ...1...