4.3 Pilot fire lighting. 

For a reasonable period of time, approximately 24 hours, it must not exceed 50% of the Maximum load allowed 

by the manufacturer. Before lighting the fire, ensure that nothing delivered with the equipment has stayed inside (such as gloves, 

spray paint ...). 

4.4. Combustion control. 

The appliance has mechanisms to regulate combustion. 

4.4.1. Primary register. 

The primary register is used to control the air intake which comes into the combustion chamber to the base 

of the fire through the vermiculite at the back. The primary damper should be used mainly for ignition and, if necessary, as a help for 

the combustion. To locate the control handle of the register and its use, see picture ‘C.9’ from the ANNEX document. 

4.4.2. Secondary register. 

The secondary register is used to control the air entering the combustion chamber from the top. The 

secondary register is used as combustion intensity adjustment. To locate the register control handle and to know how to use it see 

picture “C.10” of the ANNEXED document.

 

 

4.4.3. Tertiary or safety air.

 

The appliance has a fixed air supply through the rear vermiculite, under the deflector, to prevent possible 

deflagerations and improve combustion. 

4.5 Fire lighting.

 To light the fire, use suitable materials for this purpose, such as heat pads, paper, dry and thin branches. 

DO NOT 

USE GASOLINE, SOLVENTS OR ALCOHOL

. To see the correct position, see picture "C.5" of the ANNEXED document, then light 

the fire using a suitable material. Once the fire is lit keep the door and the registers open for a reasonable time to prevent condensation 

on the door. When the apparatus is hot enough close the door, adjust the primary register to avoid excessive combustion and control 

the intensity of fire by the child record. 

 

4.6 Loading and reloading of fuel.

 Do not exceed the maximum allowed load or reload. (See Table of Technical specifications). 

4.7 Door opening.

 The door must be opened only for reloading. To open it, follow the steps described in picture “C.1.A" or “C.1.B” 

of the ANNEXED document. 

4.8 Operation in adverse weather conditions. 

It is possible for the device to malfunction due to sudden or unexpected weather 

changes, causing: low pressure, ebb currents of air into the smoke duct. When these phenomena are observed it is advisable to close 

the combustion register and turn the equipment off. 

4.9 Fire Prevention. 

You must not place any flammable element outside the safety distance from the fireplace described in the table 

in section 1.1 Technical specifications. You shall also take special precautions if there are children and elderly people present. In 
case of fire, push away all the people around it, close the registers as much as possible and notify the Firefighting service. 

4.10 Dilations of the sheet.

 

Materials subject to temperature changes undergo dilatations. This phenomenon can cause sporadic 

metallic noises more or less frequently. These are completely innocuous and do not mean any risk or problem for its operation. 

 

5.1 Maintenance. 

An appropriate and regular maintenance of both the appliance and the installation contributes greatly to its good 

performance. It is important to perform periodic and complete controls of the equipment and of the ducts and installation. Thus, for 

your safety and comfort, 

some of our dealers offer a servicing contract for your device. Please contact your dealer for this 

service. 
5.1.1 Locking mechanisms.

 You need to make sure no mechanisms are locked (registers, door, air inlet, etc.) after an extended 

shutdown period. 

5.1.2. Spare parts. 

Use only original spare parts, or parts recommended by Manufacturas Rocal, S.A. See picture on section “V” of 

the ANNEXED document. 

5.2. Cleaning.

 It is important for the appliance to be clean of ash so that all mechanisms work properly. To clean the body of the 

device 

use the cleaning dry cloth given with the appliance or similar. Do not use current cleaning products

.

 

5.2.1 Glass. 

You must turn the device off to clean the glass. The products used must not come into contact with the metal parts of 

the door or the ceramic board; the aggressiveness of these products can cause a corrosion process of the equipment. To make 
cleaning the glass easier, the frontal secondary air difuser and the side doors can be opened, follow the steps indicated in the images 

“C.2” to open side doors and “C.2” to “C.4” to open the difuser. 

5.2.2 Ash box. 

Empty the box only when the appliance is completely turned off,

 ensuring that the ashes do not contain any 

burning coals

; in which case you should deposit them in a metal bucket. To access the ash basin follow the steps shown in pictures 

“C.6” and “C.7” or “C.8” of the ANNEXED document. 

 

5.2.3. Flue liner. 

 It is important to keep the flue liner clean. It gets dirty depending on the fuel used, on a slower or faster combustion, 

etc. You need to clean the flue liner at least once per season. It is mandatory for a specialist to review it periodically. To access the 

flue liner follow the steps shown in pictures “C.11” to “C,14” of the ANNEXED document follow the steps shown in picture “C.16” if 

you have +Plus 250. 

5.2.4. Painting.

  The heat-resistant paint that covers the whole device (the combustion chamber, the interior, the front door, the 

frame which covers the joints, etc.), resists up to 600ºC of temperature and releases a slight characteristic odor that disappears with 
the first ignitions. It is necessary to regularly check the condition of the paint and correct it when necessary. 
This paint can be damaged when; the temperature exceeds 600ºC, fuels with too much humidity or non-recommended fuels are used, 

it is installed in humid environments and / or salinity in the environment (seawater), it is in contact with chemical cleaning products or 

with water (inputs through the duct, etc.). 

Use exclusively "Rocal heatproof spray paint”. 

 

Rocal offers various optional items, contact your local dealer to purchase these items. Some of the items are shown below: 

Item 

Code 

Description 

ECOntrol 

C7000 

Intelligent combustion control 

4 sides frame 

***** 

Four side frame of 4 cm 

Decorative frame NERO 

***** 

Four frame sides of 10 cm with decoration NERO 

IMPORTANT:   -The interior vermiculite parts SHOULD NOT RECEIVE IMPACTS when refueling is performed.  

If  any  of  these  parts  crack,  but  is  properly  set  in  its  place,  THE  PROPER  OPERATION  OF  THE 
APPLIANCE SHALL NOT BE ALTERED AND THERE IS NO POTENTIAL RISK. The equipment can be 
used normally. These cracks do not entail any manufacturing defect so they do not fall under guarantee

.

 

5. CLEANING AND MAINTENANCE 

CAUTION: With the appliance running, the inside compartment must remain completely closed. You can only 

access it for ash disposal.

 

6. OPTIONAL COMPLEMENTS 

Summary of Contents for G 450 TC

Page 1: ...8380 G 450 TC G 450 TC Plus 250 MANUAL DE CARACTERISTICAS INSTALACION Y FUNCIONAMIENTO USER S GUIDE ON CHARACTERISTICS ASSEMBLY AND OPERATING MANUEL DES CARACTERISTIQUES INSTALLATION ET FONCTIONNEMENT...

Page 2: ...oy your purchase L quipe de Rocal vous remercie pour votre confiance en nous et pour choisir un de nos produits Profitez de votre achat Il team di Rocal La ringrazia per la fiducia accordataci e per a...

Page 3: ...ntrol de la combusti n 5 4 4 1 Registro primario 5 4 4 2 Registro secundario 5 4 4 3 Aire terciario o de seguridad 5 4 5 Encendido 5 4 6 Carga y recarga de combustible 5 4 7 Apertura de la puerta 5 4...

Page 4: ...Certificado 1880 CPR 035 20 1880 CPR 037 20 1 2 Detalle de los componentes de entrega Compruebe que dispone de todos los componentes descritos a continuaci n en relaci n a la imagen del apartado II d...

Page 5: ...e 2 6 Nicho del hogar El nicho de hogar debe construirse con materiales incombustibles y no debe descansar encima del aparato ni en los puntos de contacto como por ejemplo el marco frontal imagen B 4...

Page 6: ...e La recarga debe efectuarse cuando la llama se apague y solo queden ascuas No debe superarse la C M A carga m xima autorizada ni en la carga ni en la recarga V ase tabla de Caracter sticas t cnicas 4...

Page 7: ...a los pasos descritos en la imagen C 16 si dispone de Plus 250 5 2 4 Pintura La pintura antical rica que reviste todo el aparato la c mara de combusti n el interior la puerta frontal el marco tapa jun...

Page 8: ...a de Combusti n del aparato Esperar que el proceso de polimerizaci n de la pintura finalice esto puede tardar de uno a varios encendidos Revisi n de materiales aislantes tales como fibra de vidrio mad...

Page 9: ...hting 11 4 4 Combustion control 11 4 4 1 Primary register 11 4 4 2 Secondary register 11 4 4 3 Tertiary or safety air 11 4 5 Fire lighting 11 4 6 Loading and reloading of fuel 11 4 7 Door opening 11 4...

Page 10: ...mm 4 7x 120 mm aluminium ring 5 4x Levelling and adjustable foots 6 Documentation bag output declaration energy label guarantee technical sheet and installation and operating characteristics manual 7...

Page 11: ...12 9 3 5 2 11 7 4 4 1 5 10 6 5 4 1 8 5 6 3 1 6 4 The length is using 120 mm smooth insulated tube and a wide radius elbow if flexible non insulated conduits are used and or there are more elbows the d...

Page 12: ...cts and installation Thus for your safety and comfort some of our dealers offer a servicing contract for your device Please contact your dealer for this service 5 1 1 Locking mechanisms You need to ma...

Page 13: ...irst lighting Flammable or combustible items in the enclosure or surrounding walls of the equipment Crack in the combustion chamber of the equipment Wait for the polymerization process of the paint to...

Page 14: ...e de la combustion 16 4 4 1 Registre primaire 16 4 4 2 Registre secondaire 16 4 4 3 Tertiaire ou air de s curit 16 4 5 Allumage 16 4 6 Chargement et rechargement de combustible 16 4 7 Ouverture de la...

Page 15: ...R 037 20 1 2 D tail des composants de livraison V rifiez que vous disposez de tous les l ments d crits ci dessous qui figurent sur l image du paragraphe II du document ANNEXE 1 Corps de la chemin e 2...

Page 16: ...verre papier de craie etc 2 7 Ventilation Il est imp ratif que la niche o l appareil est install ventilation disponible 2 7 1 Ventilation du caisson Il convient de pr voir la mise en place de ouvertu...

Page 17: ...rte r glez le registre primaire afin d viter une combustion excessive et contr lez l intensit du feu l aide du registre secondaire 4 6 Chargement et rechargement de combustible Le chargement maximal a...

Page 18: ...et C 5 ou C 6 du document ANNEXE 5 2 3 Conduit de fum es Il est important d liminer toute sorte de r sidu dans le conduit d vacuation des fum es Les salet s qui s accumulent dans celui ci peuvent tre...

Page 19: ...chambre de combustion de l appareil Attendre que le processus de polym risation de la peinture se termine ce qui peut durer de un plusieurs allumages Examiner les mat riaux isolants tels que la fibre...

Page 20: ...ione 22 4 4 1 Registro primario 22 4 4 2 Registro secondario 22 4 4 3 Terziario o aria di sicurezza 22 4 5 Accensione 22 4 6 Carica e ricarica di combustibile 22 4 7 Apertura de la puerta 22 4 8 Funzi...

Page 21: ...SOTTO COPERTINA Anno Certificazione 2020 2020 N del certificato 1880 CPR 035 20 1880 CPR 037 20 1 2 Dettaglio dei componenti di consegna Verificate che siano presenti tutti i componenti di seguito des...

Page 22: ...al caso necessario un isolamento adeguato 2 6 Nicchia del focolare La nicchia del focolare deve essere realizzata con materiali non combustibili e non deve appoggiare sull apparecchio o nei punti di c...

Page 23: ...a che nella ricarica Vedi tabella di Specifiche tecniche 4 7 Apertura de la puerta Si deve soltanto aprire per fare la ricarica Per l e apertura seguite i passi descritti nelle immagini C 1 A o C 1 B...

Page 24: ...magini C 11 a C 14 seguite i passi nella immagini C 16 se hai Plus 250 5 2 4 Vernice La vernice termoresistente che riveste tutto l apparecchio la camera di combustione l interno lo sportello frontale...

Page 25: ...amera di Combustione dell impianto Aspettare finche il processo di polimerizzazione della vernice sar finito per questo possono essere necessarie una o pi accensioni Controllo di materiali isolanti co...

Page 26: ...role de combust o 28 4 4 1 Registro prim rio 28 4 4 2 Registro secundario 28 4 4 3 Ar terci rio ou de seguran a 28 4 5 Igni o 28 4 6 Carregamento e reabastecimento 28 4 7 Apertura de la puerta 28 4 8...

Page 27: ...XO COBERTO Ano de certifica o 2020 2020 N mero de certifica o 1880 CPR 035 20 1880 CPR 037 20 1 2 Detalhe componentes de entrega Certifique se de que voc tem todos os componentes descritos abaixo com...

Page 28: ...u em pontos de contato como a estrutura frontal veja imagem B 2 do documento Anexado 2 7 Ventila o imperativo que o nicho onde o aparelho est instalado de ventila o dispon veis 2 7 1 Ventila o de nich...

Page 29: ...e deixar o aparelho apagar se 4 9 Preven o de inc ndios Nenhum elemento deve inflam vel dentro da dist ncia de seguran a descritos na tabela na sec o 1 1 Caracter sticas t cnicas apontam do dispositi...

Page 30: ...da por combust veis l quidos n o autorizados pelo fabricante etc Neste caso necess rio repintar todas as reas danificadas antes do per odo de paralisa o prolongada do equipamento Utilize exclusivament...

Page 31: ...ra de combust o ou nas proximidades Rachadura na c mara de combust o do aparelho Espere que o processo de polimeriza o depintura esteja conclu do Isso pode necessitar de v rios acendimentos Revis o do...

Page 32: ...82 Performance 85 4 Particle concentration 17 6 mg Nm3 Particle concentration 17 1 mg Nm3 NOx concentration at 13 of O2 101 mg Nm3 NOx concentration at 13 of O2 101 mg Nm3 OGC concentration at 13 of...

Page 33: ......

Page 34: ...1 ANEXO ANNEX ANNEXE ANESSO I G 450 TC...

Page 35: ...2 I G 450 TC Plus 250...

Page 36: ...3 II 1 11 13 10 4 2 5 3 6 7 8 9 12...

Page 37: ...4 III 1 2...

Page 38: ...5 III 1 2 3 4 5 6...

Page 39: ...6 III 7 8 9 9 1 Plus 250 9 2 Plus 250 10...

Page 40: ...7 III A 1 A 2 A 3 B 1 B 1 B 2...

Page 41: ...8 III B 3 B 4...

Page 42: ...9 IV C 1 A C 1 B C 2 C 3 C 4 C 5...

Page 43: ...10 IV C 6 C 7 C 8 C 9 C 10 C 11...

Page 44: ...11 IV C 12 C 13 C 14 C 15 C 16 C 17...

Page 45: ...12 IV C 18 C 19...

Page 46: ...E 4 2xM1870 200 1 2xM1870 200 1 5 1xM1870 80BD 1xM1870 80BD 6 7 8 1xVRM1870 6 1xVRM1870 6 9 3xVRM1870 1 3xVRM1870 1 10 3xVRM1870 2 3xVRM1870 2 11 3xVRM1870 8 3xVRM1870 8 12 1xVRM1870 7 1xVRM1870 7 13...

Page 47: ...14 NOTES...

Page 48: ...1...

Reviews: