12
Item
Code
Description
Log store
C1000
Ash vaccum cleaner
ASPIRADOR
1 inlet diffuser
D0001
1 inlet narrow diffuser
D0002
2 inlets diffuser
D0006
2 inlet snarrow diffuser
D0007
3 inlets diffuser
D0011
4 inlets diffuser
D0016
1 exit diffuser
D1001
1 exit narrow diffuser
D1002
2 exits diffuser
D1006
2 exits narrow diffuser
D1007
3 exits diffuser
D1011
4 exits diffuser
D1016
Below is a table of possible anomalies, their causes and solutions:
PROBLEM
CAUSE
SOLUTION
1. Rejects smoke and / or
insufficient draught
Incorrect duct
Lack of air supply for combustion
Incorrect position of registers
Dirty flue duct
Duct servicing*:
-connection
-diameter
-leaks
-insufficient length
-outdoor access
-possible elements blocking the exit
Check vents and / or outside air supply. Simultaneous
operation with other ventilation devices and / or heating
Setting the register
Contact a professional to clean flue duct. If the problem
persists, contact your dealer.
2.
Excessive dirt on glass
Incorrect duct
Inappropriate fuel
Overly closed registers
Revise section on insufficient flue (below).
Use recommended fuel
Adjust registers
3. Glass bleaching or colour
fading of the plate
Excessive temperature caused by excessive heat in
the combustion chamber
Check the fuel load avoiding overheating
Adjust registers
4. Poor heating
Inappropriate fuel
Insufficient load
Combustion control registers in the wrong position
Use recommended fuel
Adding fuel
Adjust registers
5. Venting smoke and / or
gases from the front, bad
smell
First lighting
Flammable or combustible items in the enclosure or
surrounding walls of the equipment
Crack in the combustion chamber of the equipment
Wait for the polymerization process of the paint to finish;
this can take from one to several lightings.
Review of insulating materials such as fiberglass,
fireproof wood or any inflammable elements and replace
them.
Check for tightness and if you discover a crack, please
contact your dealer.
6. Excessive draft
Incorrect duct
Combustion control registers in the wrong position
Duct servicing
- Excessive length
- Check Depression
- Incorrect diameter
- Check door gasket
7. Unintentional sliding of the
sliding door
The door tends to go up when opened.
The door tends to close when opened
Install parts to adjust the door opening follow the steps
described in the images “C.2” and “C.13” of the attached
document
Remove parts to adjust the door opening following the
steps described in the images “C.2” and “C.14” of the
attached document
The CE label is located on the appliance.
This label contains technical data and
OF number.
(This number can also
be found in the guarantee).
THIS NUMBER IS ESSENTIAL FOR ORDERING SPARE PARTS.
7. PROBLEMS: CAUSE AND SOLUTION
8. CE INFORMATION
WARNING:
-
All tests are carried out in observance of Regulationsm UNE-EN 13229:2002 - UNE-EN 13229:2002/A2:2005 - UNE-
EN 13229:2002/AC:2006– UNE-EN 3229:2002/A2:2005/AC:2007
-
The review of the equipment, the installation and ducts
must be carried out by a professional.
-
In case of doubt regarding the described herein, please contact your Rocal dealer.
-
FAILURE TO COMPLY WITH THE OBLIGATIONS DESCRIBED HEREIN OR IMPROPER HANDLING OF THE
EQUIPMENT SHALL
EXONERATE THE MANUFACTURER OF ANY LIABILITY.
Summary of Contents for G 450 TC
Page 33: ......
Page 34: ...1 ANEXO ANNEX ANNEXE ANESSO I G 450 TC...
Page 35: ...2 I G 450 TC Plus 250...
Page 36: ...3 II 1 11 13 10 4 2 5 3 6 7 8 9 12...
Page 37: ...4 III 1 2...
Page 38: ...5 III 1 2 3 4 5 6...
Page 39: ...6 III 7 8 9 9 1 Plus 250 9 2 Plus 250 10...
Page 40: ...7 III A 1 A 2 A 3 B 1 B 1 B 2...
Page 41: ...8 III B 3 B 4...
Page 42: ...9 IV C 1 A C 1 B C 2 C 3 C 4 C 5...
Page 43: ...10 IV C 6 C 7 C 8 C 9 C 10 C 11...
Page 44: ...11 IV C 12 C 13 C 14 C 15 C 16 C 17...
Page 45: ...12 IV C 18 C 19...
Page 47: ...14 NOTES...
Page 48: ...1...