background image

1

WS-415-137 / 05.15.00

Fax:

 (705)722-6031       

Email:

 [email protected]

Web:

 www.napoleon.on.ca

Wolf Steel Ltd., RR#1, 9 Napoleon Rd.,

Barrie, ON., Canada  L4M 4Y8  (705)721-1212

R-2000

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

CERTIFIED UNDER CANADIAN AND AMERICAN  NATIONAL STANDARDS, CGA 2.22, AND ANSI Z21.50 RESPECTIVELY FOR VENTED GAS FIREPLACES.

MILLIVOLT SYSTEM

INSTALLATION AND OPERATION INSTRUCTIONS FOR

VENTED GAS FIREPLACE - GB20

NATURAL GAS 

 MODEL

 

GB20-N

PROPANE GAS  

MODEL

 

GB20-P

CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / AGA / CGA METHODS

WARNING: 

 If the information in these instructions is not followed exactly, a fire or

explosion may result causing property damage, personal injury or death.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapours and liquids in the vicinity of

this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

•  Do not try to light any appliance.

•  Do not touch any electrical switch.

•  Do not use any phone in your building.

•  Immediately call your gas supplier from a

neighbour's phone. Follow the gas

supplier's instructions.

•  If you cannot reach your gas supplier, call

the fire department.

Installation and service must be performed by a qualified installer, service agency or the

gas supplier.

Summary of Contents for GB20-N

Page 1: ...D UNITED STATES USING ANSI AGA CGA METHODS WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR...

Page 2: ...should not be placed on or near the fireplace Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace It is imperative that the control compartments burners...

Page 3: ...d all local and national building and fire codes This limited warranty does not cover damages caused by misuse lack of maintenance accident alterations abuse or neglect and parts installed from other...

Page 4: ...each additional 1 000ft Minimum inlet gas supply pressure is 4 5 inches water column for natural gas and 11 inches water column for propane Maximum inlet gas pressure is 7 inches water column for nat...

Page 5: ...elow The other wire laying loose in the valve control area may be at tached to a wall switch or thermostat VENTING ACTION CHECK A test for correct venting action must be made before the installed unit...

Page 6: ...strand solid core millivolt wire through the electrical hole located at the bottom left side of the unit The recommended maximum lead length de pends on wire size WIRE SIZE MAX LENGTH 14gauge 100 feet...

Page 7: ...form as colour pigments burn in during the heat activated curing process FIGURES 12 DOOR HOOD AND OPTIONAL LOUVRE REMOVAL INSTALLATION DOOR OPENING AND CLOSING Open the valve control door Release the...

Page 8: ...taken to prevent drywall dust from coming into contact with the blower or its compartment Any damage resulting from this condition is not cov ered by the warranty policy INSTALLATIONTO BE DONE BY A QU...

Page 9: ...70 1996 NATIONAL ELECTRICAL CODE in the United States The wire harness provided in this kit is a universal har ness When installed ensure that any excess wire is con tained preventing it from making c...

Page 10: ...sed slightly 1 Stop Read the above safety information on this label 2 Turn off all electric power to the fireplace 3 Turn the gas knob clockwise to off 4 Wait five 5 minutes to clear out any gas If yo...

Page 11: ...gasketing on the sides top and bottom of the door is not broken or missing Replace if necessary FLAME MUST ENVELOP UPPER 3 8 TO 1 2 OF THERMOCOUPLE THERMOPILE PILOT THERMOPILE BURNER ELECTRODE THERMO...

Page 12: ...NT COMPONENTS PART NO DESCRIPTION WS 357 01 PIEZO IGNITER WS 680 04 THERMOPILE WS 680 05 THERMOCOUPLE WS 100 053 BURNER TUBE WS 100 38 NATURAL GAS PILOT ASSEMBLY WS 100 39 PROPANE GAS PILOT ASSEMBLY G...

Page 13: ...PB DOOR TRIM POLISHED BRASS WS690 1 MILLIVOLT THERMOSTAT WS660 2 HAND HELD WIRELESS REMOTE SWITCH WS 660 010 REMOTE CONTROL ADVANTAGE WS 660 011 REMOTE CONTROL ADVANTAGE PLUS GZ550 1KT BLOWER KIT GD65...

Page 14: ...ting clean thermopile connection to the valve Reconnect replace thermopile valve Remote wall switch wire is too long too much resist ance in the system shorten wire to correct length or wire gauge Fau...

Page 15: ...column for propane Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL DO NOT OVERTORQUE Leak test with a soap and water solution...

Page 16: ...16 WS 415 137 05 15 00 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Page 17: ...17 WS 415 137 05 15 00 NOTES...

Reviews: