3. DESCRIPTION OF EACH MODULES
IMSRM02-E6
45
3.6.3 Functional description
(1) Digital input function (DI-A)
The digital input function can be used to select the memory area in the control unit to which the DI-A
module is connected, to select control RUN/STOP or alarm interlock release.
After the contact is closed, it takes a short time until the action of this device is actually
selected. Therefore, pay attention to this delay time if the device is used together with a
sequencer, etc.
Memory area selection, control RUN/STOP selection and alarm interlock
release
Selection or release can be performed depending on the open or close state of terminal numbers 1 to
8.
For memory area selection, configure an external contact circuit or use a contact output signal from
the sequencer, if necessary.
Control area
Terminal No.
1
2
3
4
5
6
7
8
1 - 2
−
×
−
×
−
×
−
×
1 - 3
−
−
×
×
−
−
×
×
1 - 4
−
−
−
−
×
×
×
×
−
: Open
×
: Close
The memory area (control area) is established by closing terminal number 5.
Connect external power (24 V DC) to the number 1 and number 6 COM (common)
terminals on the DI module so that these terminal sides become positive (+).
Unused
−−−−
−−−−
1
2
3
4
5
6
7
8
9
10
(COM)
(COM)
+
+
(1)
(2)
(4)
SET
Control RUN/STOP selection (contact closed: RUN, contact opened: STOP)
Alarm interlock release (contact closed: alarm interlock release)
(No alarm interlock function is activated if the contact is in the normally closed
state.)